Laserfiche WebLink
SWRCB,January 2006 <br /> Spill Bucket Testing Report Form <br /> This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br /> printouts from tests(f applicable)should be provided to the facility owner/operator for submittal to the local regulatory agency. <br /> 1. FACILITY INFORMATION <br /> Facility Name: COUNTRY MARKET I Date of Testing: 3/2412011 <br /> Facility Address: 1524 FRESNO AVENUE, STOCKTON, CA 95206 <br /> Facility Contact: MIKE ELIASON Phone: (209)948-9412 <br /> Date Local Agency Was Notified of Testing: 2/15/2011 <br /> Name of Local Agency Inspector(f present during testing): STACEY RIVERA <br /> 2. TESTING CONTRACTOR INFORMATION <br /> Company Name: TANK-TEK ENVIRONMENTAL CORPORATION <br /> Technician Conducting Test: MIKE LAWRENCE <br /> Credentials': ®CSLB Contractor ® ICC Service Tech. ® SWRCB Tank Tester ❑ Other(Spec) <br /> License Number(s): 803705(CSLB Contractor)—1048103-UT(ICC Service Tech.)—90-1200(SWRCB Tank Tester) <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: ® Hydrostatic ❑Vacuum ❑ Other(Specify) <br /> Test Equipment Used: TAPE MEASURE Equipment Resolution: 1/16" <br /> Identify Spill Bucket Tank i 1 <br /> Number, Stored Product, <br /> etc.) DIESEL FILL <br /> Bucket Installation Type: ® Direct Bury ❑ Direct Bury ❑ Direct Bury ❑ Direct Bury <br /> ❑ Contained in Sump ❑Contained in Sump ❑ Contained in Sump ❑ Contained in Sump <br /> Bucket Diameter: 11.50" <br /> Bucket Depth: 14" <br /> Wait time between applying 0 <br /> vacuum/water and start of test: <br /> Test Start Time(Ti): 12:00 PM <br /> Initial Reading(Ri): 12.50" <br /> Test End Time(TF): 1:00 PM <br /> Final Reading(RF): 11" <br /> Test Duration(TF—Ti): 1 HR <br /> Change in Reading(RF-RI): 1.50" <br /> Pass/Fail Threshold or Criteria: 1/16" <br /> Test Result: ❑ Pass E Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> I hereby certify that all the information contained in this report is true,accurate,and in full compliance with legal requirements. <br /> Technician's Signature: %lj��'Y �'rrz �'> Date: 3/24/2011 <br /> ' State laws and regulations do not currently require testing to be performed by a qualified contractor.However,local requirements <br /> may be more stringent. <br />