Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FO �1 <br /> UNDERGROUND STORAGE TANK Z I j rw,( <br /> OPERATING PERMIT APPLICATION-TANK INFO ION(one form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections 1,II,III,IV,and IX below) 411' <br /> ❑ 1.NEW PERMIT ® 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430a DATE EXISTING UST DISCOVERED: ai0h <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) TT I <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) <br /> Valley Pacific Petroleum-Fresno Ave Cardlock <br /> BUSINESS SITE ADDRESS 103 CITY 104 <br /> 1524 Fresno Ave Stockton <br /> II.TANK DESCRIPTION <br /> YANK ID# 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> Co 1.A STAND-ALONE TANK <br /> I Trusco ❑2.ONE IN A COMPARTMENTED UNIT. <br /> Complete one page for each com arunent in the unit. <br /> DATE UST SYSTEM INSTALLED +35 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> 1997 20,000 1 <br /> III.TANK USE AND CONTENTS <br /> TANK USE C1 la.MOTOR VEHICLE FUELING ❑ Ib.MARINA FUELING ❑ Ic.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)) <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 439a <br /> CONTENTS PETROLEUM: ❑ la.REGULAR UNLEADED ❑ lc.MIDGRADE UNLEADED ❑ Ib.PREMIUM UNLEADED 440 <br /> M 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 440a <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> 11.OTHER NON-PETROLEUM(Specify): 4406 <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I.SINGLE WALL M 2.DOUBLE WALL ❑ 95.LNKNOWN 443 <br /> PRIMARY CONTAINMENT (9 1.STEEL ❑ 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 441 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER cif): 444a <br /> SECONDARY CONTAINMENT C11.STEEL [13.FIBERGLASS [16.EXTERIOR MEMBRANE LINER S 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify): 445a <br /> OVERFILL PREVENTION 1.AUDIBLE&VISUAL ALARMS 2.BALL FLOAT 3.FILL TUBE SHUT-OFF VALVE 452 <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑1.SINGLE-WALLED M 2.DOUBLE-WALLED ❑99.OTHER <br /> SYSTEM TYPE EX 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION 0 4.SAFE SUCTION[23 CCR§2636(aX3)1 4`'' <br /> PRIMARY CONTAINMENT ❑ I.STEEL ❑ 4.FIBERGLASS Of 8.FLEXIBLE ❑ 10.RIGID PLASTIC 46 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS 8.FLEXIBLE ❑ 10.RIGID PLASTIC 4646 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE IN 1.SINGLE WALL 0 2.DOUBLE WALL ❑ 90.NONE 46+d <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT 1.STEEL IN 4.FIBERGLASS 10.RIGID PLASTIC 90.NONE 99.OTHER(Specify) 464e <br /> 464el <br /> VENT SECONDARY CONTAINMENT 0 L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC 90.NONE ❑ 99.OTHER(Specify) 464f <br /> 461Fl <br /> VR PRIMARY CONTAINMENT L STEEL 0 4.FIBERGLASS ❑ 10.RIGID PLASTIC 90.NONE ❑ 99.OTHER(Specify) 4645 <br /> 4611 <br /> VR SECONDARY CONTAINMENT 1.STEEL 0 4.FIBERGLASS ❑ 10.RIGID PLASTIC 90.NONE ❑ 99.OTHER(Specify) 464h <br /> 464h1 <br /> VENT PIPING TRANSITION SUMP TYPE ❑ I.SINGLE WALL ❑ '.DOUBLE WALL 90.NONE 4641. <br /> RISER PRIMARY CONTAINMENT 1.STEEL 4.FIBERGLASS ❑ 10.RIGID PLASTIC 90.NONE E3 99.OTHER(Specify) 464i <br /> 464'1 <br /> RISER SECONDARY CONTAINMENT ❑ 1.STEEL 4.FIBERGLASS ❑ 10.RIGID PLASTIC 90.NONE 99.OTHER(Specify) 464k <br /> 464k1 <br /> FILL COMPONENTS INSTALLED M 1.SPILL BUCKET 21 3.STRIKER PLATE/BOTTOM PROTECTOR 4.CONTAINMENT SUMP 45la-c <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE M 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469 <br /> CONSTRUCTION MATERIAL Tr-i-s-T-EE-7-73 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) �`>h <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT M 6.ISOLATION s <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: 1 certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> and in full com Iia a with I requirements. <br /> APPLICANT SIGNATURE .-.• DA 11:, 70 <br /> 7/30/2010 <br /> APPLICANT NAME(print) Mike Elinson 471. APPLICANT-TITLE Cardlock Manager „ <br /> UPCF UST-B-1/2 Rev.(12/2007) <br />