Laserfiche WebLink
CONDITIONS FOR N- 38-21-3 Page- 2 <br /> The total CO emission rate from the soil remediation system served by the internal combustion engine <br /> all not exceed 10.28 lb/MMBtu. <br /> The total VOC emission rate from the soil remediation system served by the internal combustion engine <br /> shall not exceed 16 pounds in any one day. <br /> 10. Father the overall VOC control efficiency shall not be less than 95%, or the total VOC emission rate <br /> shall not exceed 2 pounds in any one day. <br /> 1. The total VOC emission rate shall not exceed 10 tons in any one calendar year. <br /> Laboratory samples shall be taken at the initial inspection under the supervision of the APCD <br /> Inspector. Samples shall be taken from both the influent and the effluent gas stream sampling ports. <br /> ';i. Laboratory samples shall be analyzed for TPH and BTEX. <br /> 14. Sampling ports adequate for extraction of grab samples, measurement of gas flow rate, and use of an <br /> FID, PID, or other District-approved VOC detection device shall be provided for both the influent and <br /> the effluent gas streams. <br /> 15. Measurements to determine the influent and the effluent gas flow rates shall be taken at the initial <br /> 1inspection <br /> 6. Initial compliance with VOC emission rate and control efficiency requirements shall be demonstrated by <br /> the results of the laboratory samples analysis. The results shall be submitted to the District <br /> ' within 60 days of the test <br /> 17. Operation of the soil remediation system shall not exceed one(1) year without prior District approval <br /> 1 <br />