My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15453
>
2800 - Aboveground Petroleum Storage Program
>
PR0523476
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2019 3:19:48 PM
Creation date
10/2/2018 11:28:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0523476
PE
2832
FACILITY_ID
FA0015491
FACILITY_NAME
PROFLEET TRUCK LUBE
STREET_NUMBER
15453
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95242
APN
02519006
CURRENT_STATUS
01
SITE_LOCATION
15453 N THORNTON RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PROFLEET TRUCK LUBE 15453 N THORNTON RD LODI March 25 2015 <br /> .SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 723 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping ❑V ❑R ❑COS <br /> 724 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ❑V ❑R ❑COS <br /> 727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 728 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V ❑R ❑COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ■V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) . <br /> Item# Remarks <br /> 601 CFR 112.7 Plan that does not follow the sequence specified in this section lacks a cross-referencing section. <br /> The Spill Prevention, Control, and Countermeasure(SPCC) Plan does not follow the order or requirements in 40 CFR <br /> Part 112, and a cross-reference was not provided. If you do not follow the sequence specified in 40 CFR 112 for the <br /> Plan, you must prepare an equivalent Plan and supplement it with a section cross-referencing the location of <br /> requirements in 40 CFR 112 and the equivalent Plan. Immediately amend the SPCC Plan to include a cross-reference <br /> or to follow the required sequence. <br /> This is a minor violation. <br /> 613 CFR 112.7(e) Failed to conduct inspections or maintain records for 3 years. <br /> Copies of inspection and testing records for 11-1-13 through 12-17-13 and 8-6-14 through present were not found on <br /> site. Inspections and tests must be conducted in accordance with the written procedures developed in the Spill <br /> Prevention, Control, and Countermeasure(SPCC) Plan. Records of these inspections and tests must be signed by <br /> the appropriate supervisor or inspector and kept on site with the SPCC Plan for a period of three years. Immediately <br /> locate a copy of all inspection and testing records for the last three years, maintain them on site, and submit copies <br /> to the EHD. <br /> This is a Class II violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): ARIS VELOSO, Senior REHS (209)468-3453 03/25/2015 <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.