Laserfiche WebLink
D. Results of Testing/Servicing <br />Software Version Installed: 132.00 <br />f`mmnlata tha fniinwinn rharklict- <br />RECENED <br />JUN 01 2017 <br />Ent\etnnRln.rt-rt�Tn,,. (�Fn.�_TIN <br />xi Yes <br />❑ No' <br />Is the audible alarm operational? <br />C Yes <br />❑ No' <br />Is the visual alarm operational? <br />xfj Yes <br />u No' <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />z1 Yes <br />❑ No' <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br />proper operation? <br />x Yes <br />u No' <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />❑ N/A <br />x Yes <br />❑ No` <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br />❑ N/A <br />detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut -down? (Check all that apply) <br />d7Sump/Trench Sensors; El Dispenser Containment Sensors. Did you confirm positive shut -down due to leaks and sensor <br />failure/disconnection? ®Yes; []]No. <br />x Yes <br />n No' <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill prevention <br />❑ N/A <br />valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent <br />of tank capacity does the alarm trigger? 90 % <br />Yes" <br />k) No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />manufacturer name and model for all replacement parts in Section E, below. <br />Yes' <br />iO No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ElProduct; mWater. If <br />es, describe causes in Section E, below. <br />x� Yes <br />❑ No' <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />X Yes <br />❑ No' <br />Is all monitoring equipment operational per manufacturer's specifications? <br />in bection a oeiow, aescrioe now ano wnen mese aenciencies were or win oe correctea. <br />E. Comments: <br />Monitoring System Certification Page of 12/07 <br />