My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2800 - Aboveground Petroleum Storage Program
>
PR0536558
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2019 4:20:05 PM
Creation date
10/2/2018 11:53:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0536558
PE
2832
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
162
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility Pilot Flying J #617 address 15237 N. Thornton Rd. Lodi, CA Inspection Aug 16, 2011 <br /> Name: <br /> VIOLATIONS <br /> # V v Code Section HSC=CA Health and SafetyCode,CFR=Code of Federal Regulations;V=Violation;RV=Repeat violation <br /> Specific requirements of HSC 25270.4.5(a)are identified as CFR code sections beginning with 112 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were made, <br /> 48 CFR 112.8(c)(6) inspect containers and container supports;or keep records of inspections and tests,or provide <br /> equivalence as allowed by CFR 112.7(a) 2 <br /> 49 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils,or provide equivalence <br /> as allowed by CFR 11 2.7 a (2) <br /> 50 CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices,or provide equivalence as allowed <br /> by CFIR 112.7a 2 <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> discharge,or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 52 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas,or provide <br /> equivalence as allowed by CFR 11 2.7 a 2 <br /> 53 CFR 11 2.8(c) 11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> capacity that will hold the volume of the largest container plus sufficient freeboard to contain precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed, or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> 55 CFR 112.8(d)(2) Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not in <br /> service or in standby service for an extended time,or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 56 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction,or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 57 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances,or provide equivalence as <br /> allowed by CFR 11 2.7 a 2 <br /> 58 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation,modification,construction, <br /> relocation,or replacement,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 59 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and other <br /> oil transfer operations,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 999 Other: See attached"Continuation-Official Inspection Report'for violation(s)not listed above. <br /> On site to conduct a routine aboveground storage tank inspection. <br /> No violations observed at time of inspection. <br /> Note: <br /> Three 20,000 gallon diesel aboveground storage tanks were put into operation on 8-13-11. The Spill <br /> Prevention Control and Countermeasures(SPCC) Plan for your facility has not yet been updated. Per <br /> Code of Federal Regulation(CFR) 112.5(a) Amend the SPCC Plan in accordance with the general <br /> requirements in section 112.7, and with any specific section of this part applicable to your facility, when <br /> there is a change in the facility design, construction, operation, or maintenance that materially affects its <br /> potential for a discharge as described in section 112.1(b). Examples of changes that may require <br /> amendment of the Plan include, but are not limited to: commissioning or decommissioning containers; <br /> replacement, reconstruction, or movement of containers; reconstruction, replacement, or installation of <br /> piping systems; construction or demolition that might alter secondary containment structures; changes of <br /> product or service; or revision of standard operation or maintenance procedures at a facility. An <br /> amendment made under this section must be prepared within six, and implemented as soon as possible, <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY <br /> RATE.THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY YME AT EHD'S CURRENT HOURLY RATE. <br /> Inspe Phone: Received By. Title: <br /> (209)468-3453 <br /> EHD 28-02 Rev 2/19/10 age 3 APSA INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.