My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2800 - Aboveground Petroleum Storage Program
>
PR0536558
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2019 4:20:05 PM
Creation date
10/2/2018 11:53:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0536558
PE
2832
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
162
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> Appendix VI <br /> ,IUN 02 2014 <br /> MONITORING SYSTEM CERTIFICATI ftIRONMENTAL. Hip:ALTH <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 29,�'a#W a of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information Pilot Flying J 617 <br /> Facility Name: y 9 Bldg.No.: <br /> Site Address: 15100 N Thornton Rd City: Lodi Zip: 95242 <br /> Facility Contact Person: Manager Contact Phone No.: 20( 9 ) 339-4066 <br /> Make/Model of Monitoring System: TLS-350 Date of Testing/Servicing:0 5 / 15/ 2 0 1 4 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected/serviced: <br /> Tank ID: _ Tank ID: <br /> L In-Tank Gauging Probe. Model: u In-Tank Gauging Probe. Model: <br /> E Annular Space or Vault Sensor. Model: _ ❑ Annular Space or Vault Sensor. Model: <br /> C Piping Sump/Trench Sensor(s). Model: _ ❑ Piping Sump/Trench Sensor(s). Model: <br /> E Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> E Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> E Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> E Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> E Other�seecify equipment t e and model in Section E on Pae 2). C Other(specifX equipment t e and model in Section E on Page 2. <br /> Tank ID: Tank ID: <br /> r- In-Tank Gauging Probe. Model: n In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: u Annular Space or Vault Sensor. Model: <br /> E Piping Sump/Trench Sensor(s). Model: ❑ Piping Sump/Trench Sensor(s). Model: <br /> E Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> E Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> E Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> E Tank Overfill/High-Level Sensor. Model: n Tank Overfill/High-Level Sensor. Model: <br /> E Other(specify equipment t e and model in Section E on Pae 2). Others ecif equipment t e and model in Section E on Pae 2). <br /> Dispenser ID: 28M Dispenser ID: 28S <br /> 1�_ Dispenser Containment Sensor(s). Model: 794380.208 K, Dispenser Containment Sensor(s). Model: 794380-208 <br /> $t Shear Valve(s). C Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chains. <br /> Dispenser ID: 29M Dispenser ID: 29S <br /> x Dispenser Containment Sensor(s). Model: 794380-208 C Dispenser Containment Sensor(s). Model: 794380-208 <br /> X Shear Valve(s). C Shear Valve(s). <br /> Dispenser Containment Float s)and Chain(s). ❑ Dispenser Containment Float(sj and Chain(s). <br /> Dispenser ID: 30M Dispenser ID: 30S <br /> >E Dispenser Containment Sensor(s). Model: 794380-208 J0 Dispenser Containment Sensor(s). Model: 794380-20e <br /> K_ Shear Valve(s). xj Shear Valve(s). <br /> E Dispenser Containment Floats and Chains ❑ Dispenser Containment Floats and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - 1 certify that the equipment Identified in this document was Inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verity that this information Is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): xi System set-up 91 Alarm history report <br /> i <br /> Garca <br /> Technician Name(print): Issac Signature: <br /> Certification No.: 842806 License.No.: 804431 <br /> Testing Company Name: Jones Covey Group, Inc. Phone No.: 88( 8 ) 972-7581 <br /> Testing Company Address: 9595 Lucas Ranch Rd.#100 Rancho Cucamonga CA,91730 Date of Testing/Servicing:0 5 / 15/ 2 0 1 4 <br /> Monitoring System Certification Page of 12107 <br />
The URL can be used to link to this page
Your browser does not support the video tag.