My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2800 - Aboveground Petroleum Storage Program
>
PR0536558
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2019 4:20:05 PM
Creation date
10/2/2018 11:53:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0536558
PE
2832
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
162
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f-IVEC) <br /> Appendix VI 0 9 2015 <br /> ENVIRONMENTAL, <br /> MONITORING SYSTEM CERTIFICATION fJr-AI-o..,^ <br /> -r79 n-rq Ar..^IT <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information Pilot-FI In J#617 <br /> Facility Name: y 9 Bldg.No.: <br /> Site Address: 15100 N.Thornton City: Lodi Zip: 95242 <br /> Facility Contact Person: Manager Contact Phone No.: 20( 9 ) 339-4066 <br /> Make/Model of Monitoring System: TLS 350 Date of Testing/Servicing: 0 5 / 13/ 2 0 1 5 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicates ecific equipment inspected/serviced: <br /> Tank ID: Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: _ ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment t e and model in Section E on Pa2e 2). ❑ Other(s2ecify equipment t e and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify eq ui ment type and model in Section E on Pae 2). ❑ Other(specify equipment t e and model in Section E on Pae 2). <br /> Dispenser ID: 22M Dispenser ID: 229 <br /> C Dispenser Containment Sensor(s). Model: 794380-209 x Dispenser Containment Sensor(s). Model: 794380-208 <br /> )0 Shear Valve(s). n Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chains . Ll Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 23M Dispenser ID: 23S <br /> C Dispenser Containment Sensor(s). Model: 794380-208 U Dispenser Containment Sensor(s). Model: 794380-208 <br /> JO Shear Valve(s). U Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chains. ❑ Dis enser Containment Floats and Chains. <br /> DispenserlD: 24M Dispenser ID: 249 <br /> ki Dispenser Containment Sensor(s). Model: 794380-208 n Dispenser Containment Sensor(s). Model: 794380-208 <br /> jo Shear Valve(s). n Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chains ❑ Dispenser Containment Floats and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): 91 System set-up C Alarm history report <br /> Technician Name(print): Issac Garcia Signature: �s _Z_ — - <br /> Certification No.: 842806 License.No.: 804431 <br /> Testing Company Name: Jones Covey Group, Inc. Phone No.: 88( 8 1 972-7581 <br /> Testing Company Address: 9595 Lucas Ranch Rd.#100 Rancho Cucamonga CA,91730 Date of Testing/Servicing:0 5 / 13/ 2 0 1 5 <br /> Monitoring System Certification Page of 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.