My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
16401
>
2800 - Aboveground Petroleum Storage Program
>
PR0528828
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:38 AM
Creation date
10/3/2018 2:47:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528828
PE
2832
FACILITY_ID
FA0009357
FACILITY_NAME
MID VALLEY AGRICULTURAL SERVICES, INC
STREET_NUMBER
16401
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
CURRENT_STATUS
01
SITE_LOCATION
16401 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: FDat.-.MID VALLEY AGRICULTURAL SERVICES, INC 16401 E HWY 26 , LINDEN ber 08, 2018 <br /> Other Violations <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 203 CFR 112.3 Failure to implement the SPCC Plan. <br /> Page 22 of the SPCC plan calls for the posting of procedures referred to as"Appendix C'near unloading and <br /> loading areas. Procedures outlined in"Appendix C'were not observed near loading and unloading areas and facility <br /> personnel could not point out the procedures near the loading and unloading areas.The owner or operator or an <br /> onshore or offshore facility subject to this section must prepare in writing and implement a Spill Prevention Control <br /> and Countermeasure Plan (hereafter"SPCC Plan" or"Plan")," in accordance with§ 112.7 and any other applicable <br /> section. Implement the SPCC plan as written or amend the SPCC plan to reflect current practices and procedures. <br /> This is a minor violation. <br /> 301 CFR 112.5(a) Failed to amend Plan as necessary. <br /> The SPCC plan lists audible alarms used for overfill prevention on the two 10,000 gallon tanks. Facility personnel <br /> stated that audible alarms were not part of the system. Section 11.2.2 of the SPCC plan states that there are no <br /> manual valves installed on the diked areas of the facility to facilitate drainage.A manual drainage valve was <br /> observed crossing the secondary containment wall of the 10,000 gallon tanks. The drainage valve was observed <br /> near ground level,went across the secondary containment wall and terminated above a drain on the outer side of <br /> the wall. The drain was said to lead to the facilities retention pond.The Spill Prevention, Control, and <br /> Countermeasure(SPCC)Plan must be amended when there is a change in the facility design, construction, <br /> operation, or maintenance that materially affects its potential for a discharge,within 6 months of the change, and <br /> implemented as soon as possible, not later than 6 months following preparation of the amendment. Immediately <br /> make all necessary amendments to the SPCC Plan to accurately represent the procedures and policies currently in <br /> place at the facility. <br /> This is a minor violation. <br /> FA0009357 PR0528828 SCO01 10/08/2018 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />