Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209) 468-3433 Web:www.sigov.org/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> FacilName Mid Valley Agricultural Services Addr ss: 16401 E. Hwy 26, Linden Date: Jan <br /> Jan 8, 2013 <br /> FacilitySam Robinson Tltle: Safe /Com Ilnc Ofc Phone: 931-7600 <br /> Contact: � p <br /> Inspection XRoutine ❑Follow up ❑Complaint—ID#: ❑Other. <br /> Type: <br /> (Authority r: Wrispecti) Sam Robinson Safet /Com Ilnc Ofc <br /> Consent for: 1�Inspection )B;Sampling J�Photos Granted by: Title: y p <br /> AST Emulsion Oil MOTOR OIL MOTOR OIL DSL 87 GAS USED OIL MOTOR OIL MOTOR OIL Total Facility Shell 46770 <br /> Content Capacity(gal): <br /> Shell 13000 6500 6500 10000 10000 350 300 120 SPCC Plan 5-year 2011 <br /> Capacity Review Date: <br /> SPCC Plan type: ❑APSA SPCC conditionally exempt(HSC 25270.4.5(b)) )Fully or partially Professional Engineer certified ❑Self-certified <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=California Health and Safety Code;CFR=Code of Federal Regulations <br /> Cl=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> - Aboveground Petroleum Storage Act <br /> 101 HSC 25270.4.5(a) Failed to prepare a written SPCC Plan in accordance with CFR Part 112 <br /> 102 HSC 25270.4.5(a) Failed to conduct periodic inspections of the storage tank to assure compliance with CFR Part 112 <br /> 103 HSC 25270.6(a) Failed to file business plan or annual tank facility statement if capacity>1 OK gallons and>t5% <br /> petroleum <br /> 104 HSC 25270.6(b) Failed to submit APSA fees <br /> 105 HSC 25270.8 Failed to report spills or releases of 42 gallons or more <br /> Requirement to Prepare and Implement a SPCC Plan <br /> 201 CFR 112.3 d SPCC Plan certification b a Professional Engineer(PE)missing or incomplete <br /> 202 CFR 112.3(e) Failed to retain a copy of the SPCC Plan on site <br /> Amendment of SPCC Plan by owners or operators. <br /> 301 CFR 112.5(a) Failed to amend SPCC Plan within 6 months,or implement changes within 6 months of amendment <br /> when there is an applicable change to the facility <br /> 302 CFR 112.5(b) Failed to amend SPCC Plan within 6 months,or implement changes within 6 months of amendment <br /> after scheduled 5 year Plan review <br /> 303 CFR 112.5(b) Failed to complete a review and evaluation of SPCC plan at least once every 5 years <br /> 304 CFR 112.5(c) Failed to have a PE certify technical amendments within 6 months of change <br /> Qualified Facilities an Requirements <br /> 401 CFR 112.6(a) Tier I qualified facility failed to self-certify(1)SPCC Plan;(2)technical amendment when there was an <br /> applicable change to the SPCC Plan <br /> 402 CFR 112.6(a)(3) Tier I qualified facility SPCC Plan incomplete <br /> 403 CFR 112.6(b) Tier II qualified facility failed to self-certify(1)SPCC Plan;(2)technical amendment when there was an <br /> applicable change to the SPCC Plan <br /> 404 CFR 112.6(b)(4) Failed to provide written PE certification in a self-certified plan for alternate methods which provide <br /> environmental equivalence,or provisions in lieu of secondary containment due to impracticality <br /> ' - General Requirements for SPCC Plans <br /> 501 CFR 112.7 Failed to include a cross-referencing section for a Plan that does not follow the sequence specified in this <br /> section <br /> 502 CFR 112.7 SPCC Plan lacks full approval of management at a level of authority to commit the necessary resource <br /> to implement the Plan <br /> 503 CFR 112.7(a)(2) Failed to provide equivalent environmental protection and/or state the reasons for nonconformance and <br /> describe.the alternate methods and how they achieve equivalent environmental protection <br /> 504 CFR 112.7(a)(3) No facility diagram or diagram failed to show location and contents of each container,transfer stations, <br /> and connecting pipes. <br /> 505 CFR 112.7(a)(3)(i) SPCC Plan failed to include description of product type and storage capacity for each container <br /> 506 CFR 112.7(a)(3)(ii) SPCC Plan failed to include procedures for routine handling of products and discharge prevention <br /> measures <br /> 507 CFR 112.7 a 3 III SPCC Plan failed to show discharge or drainage controls(secondary containment),equipment,and <br /> ( )( )( ) procedures for the control of a discharge <br /> 508 CFR 112.7(a)(3)(iv) SPCC Plan failed to show countermeasures for discovery,response and cleanup of discharges <br /> Inspector. Received By: Title: <br /> Jeffrey Wong (209) 468-0335 M ek <br /> EHD 28-02 Rev 08/19/12 Pagel APSA INSPECTION REPORT <br />