Laserfiche WebLink
LIQUID SENSOR SETUP <br /> - - - - IN-TANK ALARMS <br /> L 1 :87 ANNULAR T 1 :HIGH WATER ALARM <br /> DUAL POINT HYDROSTATIC T. I :LOW PRODUCT ALARM <br /> CATEGORY : ANNULAR SPACE <br /> LIQUID SENSOR ALMS <br /> L 6:FUEL ALARM <br /> L 9:FUEL ALARM <br /> L 2:87 FILL SUMP L10:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) LII :FUEL ALARM <br /> CATEGORY : PIPING SUMP L12:FUEL ALARM <br /> L 6:SENSOR OUT ALARM <br /> L 9:SENSOR OUT ALARM <br /> L 3:87 STP-SUMP L10:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) OUTPUT RELAY SETUP LII :SENSOR OUT ALARM <br /> CATEGORY : STP SUMP - - - - - - - - - - - - L12:SENSOR OUT ALARM <br /> L 6:SHORT ALARM <br /> R 1 :87 RELAY L 9:SHORT ALARM <br /> L 4:DIESEL STP-SUMP TYPE: L1O:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) STANDARD L11 :SHORT ALARM <br /> CATEGORY : STP SUMP NORMALLY CLOSED L12:SHORT ALARM <br /> R 4:OVERFILL ALARM <br /> L 5:DIESEL FILL SUMP IN-TANK ALARMS: TYPE: <br /> TRI-STATE (SINGLE FLOAT) T 2:HIGH WATER ALARM STANDARD <br /> CATEGORY : PIPING SUMP T 2:LOW PRODUCT ALARM NORMALLY OPEN <br /> LIQUID SENSOR ALMS <br /> L 6:91 STP-SUMP L 3:FUEL ALARM IN-TANK ALARMS <br /> TRI-STATE (SINGLE FLOAT) L 9:FUEL ALARM ALL:OVERFILL ALARM <br /> CATEGORY : STP SUMP LIO:FUEL ALARM ALL:HIGH PRODUCT ALhR11 <br /> LII :FUEL ALARM ALL:MAX PRODUCT ALhRI'l <br /> L12:FUEL ALARM <br /> L 7:91 FILL SUMP L 3:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 9:SENSOR OUT ALARM <br /> CATEGORY : PIPING SUMP L10:SENSOR OUT ALARM <br /> L11 :SENSOR OUT ALARM <br /> L12:SENSOR OUT ALARM <br /> L 8:91 ANNULAR L 3:SHORT ALARM <br /> DUAL POINT HYDROSTATIC L 9:SHORT ALARM <br /> CATEGORY : ANNULAR SPACE LIO:SHORT ALARM <br /> LII :SHORT ALARM <br /> L12:SHORT ALARM <br /> RECONCILIATION SETUP <br /> L 9:DISPENSER 1-2 R 2:DIESEL RELAY - - - - - - - - - - - - <br /> TRI-STATE (SINGLE FLOAT) TYPE: <br /> CATEGORY : DISPENSER PAN STANDARD <br /> NORMALLY CLOSED AUTOMATIC DAILY CLOSING <br /> TIME: 2:00 AM <br /> L10:DISPENSER 3-4 IN-TANK ALARMS PERIODIC RECONCILIATION <br /> TRI-STATE (SINGLE FLOAT) T 3:HIGH WATER ALARM MODE: MONTHLY <br /> CATEGORY : DISPENSER PAN T 3:OVERFILL ALARM <br /> TEMP COMPENRHPION <br /> LIQUID SENSOR ALMS STANDARD <br /> L 4:FUEL ALARM <br /> LII :DISPENSER 5-6 LII :FUEL ALARM HUS SLOT FUEL METER TANK <br /> TRI-STATE (SINGLE FLOAT) L12:FUEL ALARM - - - - - - - - - - <br /> CATEGORY : DISPENSER PAN L 4:SENSOR OUT ALARM TANK MAP EMP1 <br /> Lll :SENSOR OUT ALARM <br /> L12:SENSOR OUT ALARM <br /> L 4:SHORT ALARM <br /> L12:DISPENSER 7-8 L11 :SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) L12:SHORT ALARM <br /> CATEGORY : DISPENSER PAN <br /> R 3:91 RELAY <br /> TYPE: <br /> STANDARD <br /> NORMALLY CLOSED <br />