TANK #: 1 <br /> IN-TANK ALARMS EVRiISD SETUP <br /> T 1 :HIGH WATER ALARM <br /> T 1 :LOW PRODUCT ALARM <br /> LIQUID SENSOR ALMS EVR TYPE: BALANCE <br /> L 6:FUEL ALARM <br /> L 9:FUEL ALARM BALANCE NOZZLE TYPE <br /> OUTPUT RELAY SETUPL10:FUEL ALARM VST <br /> _ _ _ _ LII :FUEL ALARM <br /> - - - - - - L12:FUEL ALARM VAPOR PROCESSOR TYPE <br /> L 6:SENSOR OUT ALARM VEEDER-ROOT POLISHER <br /> R 1 :87 RELAY 9:SENSUR OUT ALARM <br /> TYPE: L10:SENSOR OUT ALARM <br /> STANDARD Lll :SENSOR OUT ALARM <br /> NORMALLY CLOSED L12:SENSOR OUT ALARM ANALYSIS TIMES <br /> L 6:SHORT ALARM TIME: 9: <br /> AM <br /> TANK #: 2 L 9:SHORT ALARM DELAY MINUTES:ES:S: <br /> 1 <br /> L10:SHORT ALARM <br /> IN-TANK ALARMS L11 :SHORT ALARM ACCEPT HIGH ORVR: <br /> T 2:HIGH WATER ALARM <br /> L12:SHORT ALARM DISABLED <br /> T 2:LOW PRODUCT ALARM ISD SITE ALARMS <br /> LIQUID SENSOR ALMS ISD GROSS PRES FAIL ISD HOSE TABLE <br /> L 3:FUEL ALARM ISD DEGRD PRES FAIL ID FP FL HL AA RR <br /> ------------------------ <br /> L 9:FUEL ALARM ISD VAPOR LEAK FAIL O1 01 O1 02 01 UU <br /> L1U:FUEL ALARM ISD VP PRES FAIL 02 02 02 02 01 UU <br /> L11 :FUEL ALARM ISD VP STATUS FAIL 03 03 03 02 02 UU <br /> ISD SETUP FAIL <br /> L12:FUEL ALARM ISD SENSOR OUT FAIL 04 04 04 02 02 UU <br /> L 3:SENSOR OUT ALARM 05 05 05 02 03 UU <br /> L 9:SENSOR OUT ALARM ISD HOSE ALARMS 06 06 06 02 03 UU <br /> L10:SENSOR OUT ALARM ALL:FLOW COLLECT FAIL 07 07 07 02 04 UU <br /> L11 :SENSOR OUT ALARM 00 08 00 02 04 UU <br /> L12:SENSOR OUT ALARM R 4:OVERFILL ALARM <br /> L 3:SHORT ALARM TYPE; <br /> L 9:SHORT ALARM STANDARD ISD AIRFLOW METER MAP <br /> L10:SHORT ALARM NORMALLY OPEN ID SERIAL NUM LABEL <br /> L11 :SHORT ALARM ------------------------ <br /> L12:SHORT ALARM TANK #: NONE 1 26831 1-2 AFM <br /> 2 28635 3-4 AFM <br /> ISD SITE ALARMS 3 28850 5-6 AFM <br /> ISD GROSS PRES FAIL IN-TANK ALARMS 4 28825 7-8 AFM <br /> ISD DEGRD PRES FAIL ALL:OVERFILL ALARM <br /> ISD VAPOR LEAK FAIL ALL:HIGH PRODUCT ALARM <br /> ISD VP PRES FAIL ALL:MAX PRODUCT ALARM ISD FUEL GRADE HOSE MAP <br /> ISD VP STATUS FAIL 1 2 3 4 <br /> ISD SETUP FAIL FP MHH MHH MHH MHH AA <br /> ISD SENSOR OUT FAIL ------------------------ <br /> 01 201 301 901 U U 1 <br /> ISD HOSE ALARMS 02 202 302 902 U U 1 <br /> ALL:FLOW COLLECT FAIL 03 203 303 903 U U 2 <br /> 04 204 304 904 U U 2 <br /> R 2:DIESEL RELAY 05 205 305 905 5 U 3 <br /> TYPE: 06 206 306 906 5 U 3 <br /> STANDARD 07 207 307 907 5 U 4 <br /> NORMALLY CLOSED 00 208 308 908 5 U 4 <br /> TANK #: 3 SMARTSENSOR SETUP- - <br /> LABEL TABLE <br /> IN-TANK ALARMS s 1 :1-2 AFM <br /> T 3:HIGH WATER ALARM 2:AIR FLOWMETER1 : UNASSIGNED <br /> 2: BLEND3 <br /> T 3:LOW PRODUCT ALARM s 2:3-4 AFM 3: REGULAR <br /> LIQUID SENSOR ALMS CATEGORY AIR FLOW METER 4: MID GRADE <br /> 5: PREMIUM <br /> L 4:FUEL ALARM s 3:5-6 AFM 6: GOLD <br /> L11 :FUEL ALARM CATEGORY AIR FLOW METER 7: BRONZE <br /> L12:FUEL ALARM 8: SILVER <br /> L 4:SENSOR OUT ALARM s 4;7-8 AFM 9: BLEND2 <br /> LII :SENSOR OUT ALARM CATEGORY AIR FLOW METER 10: BLEND4 <br /> L12:SENSOR OUT ALARM <br /> L 4:SHORT ALARM s 5:PRESSURE SENSOR 5-6 FMC SETUP <br /> L11 :SHORT ALARM CATEGORY VAPOR PRESSURE <br /> L12:SHORT ALARM PMC VERSION: 01 .02 <br /> ER <br /> R 3:91 RELAY s TEGO <br /> CATEGORRYY VVAAPOR VALVE VAPOR PROCESSOR TYPE <br /> TYPE: VEEDER-ROOT POLISHER <br /> STANDARD s O:ATM P <br /> NORMALLY CLOSED CATEGORY ATM P SENSOR <br />