CONTACTS <br />REGULATORY AGENCY/OWNER: <br />EMPIRE ISLAND FARMING COMPANY, LLC, <br />11751 W. EIGHT MILE RD. <br />STOCKTON, CA 95215 <br />PRESIDENTS STEVE FAUGN <br />ENGINEER (SEPTIC SYSTEM DESIGN). <br />BLACK WATER CONSULTING ENGINEERS, INC. <br />605 STANDIFORD AVE, STE. N <br />MODESTO, CA 95350 <br />ENGINEER: AIA VERBURG, P.E. <br />'T,-209,753,0078 <br />ENGINEER (CIVIL SITE DESIGN) <br />BENCHMARK ENGINEERING, INC <br />915 77H ST. <br />MODESTO, CA 95354 <br />SERGIO CARRERA, RE <br />T:209,548.9300 <br />1, CONTRACTOR SHALL CONSIDER THE INFORMATION PRESENTED AS "GENERAL NOTES®" AS <br />PART OF THE CONSTRUCTION DOCUMENTSa <br />2. PRIOR TO ANY WORK BEING PERFORMED, THE CONTRACTOR SHALL CONTACT THE <br />APPROPRIATE REGULATORY AGENCIES FOR A PRE -CONSTRUCTION CONFERENCE. <br />CONTRACTOR SHALL ALSO NOTIFY THE OWNERS AND ENGINEER SEVENTY-TWO (72) <br />HOURS PRIOR TO MEETING DATE. <br />3. ENGINEER OF RECORD MUST APPROVE ANY SUBS111"U11ONS. IMMEDIATELY NOTIFY THE <br />ENGINEER OF ANY CONFLICTS BETWEEN THE DRAWINGS AND OTHER DETAILS; OR <br />EXISTING CONDITIONS NOT SHOWN OR DIFFERENT FROM THOSE SHOWN ON THE <br />DRAWINGS PRIOR 'TO COMMENCEMENT OF WORK. MATERIALS PROCURED PRIOR TO <br />RESOLUTION OF CONFLICTS SHALL BE AT THE CONTRACTOR'S RISK. <br />4THE CONTRACTOR SHALL EXERCISE DUE CAUTION AND SHALL CAREFULLY PRESERVE <br />BENCHMARKS, REFERENCE POINTS AND ALL SURVEY STAKES, AND SHALL BEAR ALL EXPENSE <br />FOR REPLACEMENT AND/OR ERRORS CAUSED BY THEIR UNNECESSARY LOSS OR <br />DISTURBANCE. ALL STREET MONUMENTS, LOT CORNERS, BENCHMARKS, AND OTHER <br />PERMANENT PIPE MONUMENTS DISTURBED DURING THE PROCESS OF CONSTRUCTION <br />SHALL BE REPLACED BY A LICENSED CIVIL ENGINEER OR SURVEYOR PRIOR TO ACCEPTANCE <br />OF THE IMPROVEMENTS, <br />5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT SECTIONS OF <br />,THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE GOVERNING BUILDING <br />JURISDICTION AND/OR THE STATE OF CALIFORNIA, LATEST EDITION, AND ALL OSHA <br />REQUIREMENTS AS THEY APPLY TO THE PROJECT. <br />& THE DRAWINGS AND SPECIFICATIONS REPRESENT THE COMPLETED PROJECT, AND DO NOT <br />INDICATETHE METHOD OR MEANS OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE <br />ALL MEASURES NECESSARY TO PROTECT THE CONSTRUCTION AND ALL ADJACENT <br />PROPERTIES DURING CONSTRUCTION, <br />7, 'THE CONTRACTOR SHALL BE RESPONSIBLE FOR. <br />A, CLEANING THE JOB SITE AT THE END OF EACH PHASE OF WORK, <br />B. REMOVING AND DISPOSING OF ALL 'TRASH, SCRAP AND UNUSED MATERIAL AT <br />THEIR OWN EXPENSE IN A TIMELY MANNER, <br />C. MAINTAINING THE SITE IN A NEAT, SAFE AND ORDERLY MANNER AT ALL TIMES, <br />D, KEEPING MATERIALS, EQUIPMENT AND TRASH OUT OF THE WAY OF OTHER <br />CONTRACTORS SO AS TO NOT DELAY THE JOB, <br />EA PROVIDING THEIR OWN SAFETY, TRAFFIC CONTROL PERMITS, RETESTING AND <br />REINSPECTION, <br />F, PROVIDING ALL WATER, POWER, SANITARY FACILITIES AND 'TELEPHONE SERVICES <br />AS REQUIRED FOR THE CONTRACTOR'S USE DURING CONSTRUCTION. <br />G, SCHEDULING INSPECTION AND TESTING OF ALL FACILITIES CONSTRUCTED UNDER <br />THIS CONTRACT. ALL TESTING SHALL CONFORM TO REGULATORY AGENCY'S <br />STANDARD SPECIFICATIONS. <br />H, FIELD CHANGES MADE WITHOUT WRITTEN AUTHORIZATION FROM THE ENGINEER. <br />L, THE CONTRACTOR SHALL PROVIDE ALL LIGHTS, SIGNS, BARRICADES, FLAGMEN, OR <br />OTHER DEVICES NECESSARY FOR PUBLIC SAFETY IN ACCORDANCE WITH THE <br />CURRENT ISSUE OF "MANUAL OF TRAFFIC CONTROLS, WARNING SIGNS, LIGHTS, <br />AND DEVICES FOR USE IN PERFORMANCE OF WORK UPON HIGHWAY" PUBLISHED <br />BY THE STATE OF CALIFORNIA BUSINESS AND TRANSPORTATION AGENCY, <br />8. THE CONTRACTOR SHALL MAINTAIN A NEATLY MARKED SET OF FULL-SIZE AS -BUILT RECORD <br />DRAWINGS SHOWING THE FINAL LOCATION AND LAYOUT OF ALL PIPING AND <br />CONDUITS, STRUCTURES AND OTHER FACILITIES, AS -BUILT RECORD DRAWINGS SHALL <br />REFLECT CHANGE ORDERS, ACCOMMODATIONS AND ADJUSTMENTS TO ALL <br />IMPROVEMENTS CONSTRUCTED. WHERE NECESSARY, SUPPLEMENTAL DRAWINGS SHALL BE <br />PREPARED AND SUBMITTED BY THE CONTRACTOR, <br />9. PRIOR TO FINAL ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL DELIVER TO THE <br />ENGINEER, ONE SET OF NEATLY MARKED AS -BUILT RECORD DRAWINGS SHOWING THE <br />INFORMATION REQUIRED ABOVE, AS -BUILT RECORD DRAWINGS SET SHALL BE CURRENT <br />WITH ALI. CHANGES AND DEVIATIONS REDLINED AS A PRECONDITION TO THE FINAL <br />PAYMENT APPROVAL AND/OR FINAL ACCEPTANCE, <br />10, THE INFORMATION SHOWN ON THE PLANS WITH REGARD TO THE EXISTING UTILITIES <br />AND/OR IMPROVEMENTS WAS DERIVED FROM FIELD INVESTIGATIONS AND/OR RECORD <br />INFORMATION. THE ENGINEER DOES NOT GUARANTEE THESE LOCATIONS TO BE EITHER <br />TRUE OR EXACT. PRIOR TO CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S <br />RESPONSIBILITY TO VERIFY ALL EXISTING IMPROVEMENTS AND TO EXPOSE <br />UNDERGROUND UTILITIES RELATED TO THE PROJECT; INCLUDING BUT NOT LIMITED TO <br />SEWER, STORM DRAIN, WATER, IRRIGATION, GAS, ELECTRICAL, ETC, AND SHALL NOTIFY <br />THE ENGINEER AND OWNER IN WRITING FOURTY-EIGHT (48) HOURS IN ADVANCE OF <br />EXPOSING THE UTILITIES SO THAT THE EXACT LOCATION AND ELEVATION CAN BE VERIFIED <br />AND DOCUMENTED. IF LOCATION AND/OR ELEVATION DIFFERS FROM THAT SHOWN ON <br />THE DESIGN PLANS, PROVISIONS TO ACCOMMODATE NEW LOCATION/ELEVATION MOST <br />BE MADE PRIOR TO CONSTRUCTION. <br />11, THE SEPTIC SYSTEM AND LEACH FIELD SHALL COMPLY WITH SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT (S.ICEHD), AND ONSITE WASTE -WATER TREATMENT <br />STANDARDS (OWTS) AND RECOMMENDATIONS OF THE SOIL SUSTAINABILITY/NITRATE <br />LOADING STUDY PREPARED BY LIVE OAK GEO ENVIRONMENTAL DATED MARCH 10, 2017, <br />SEPTIC TANK AND LEACH FIELD SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND <br />APPROVAL BY SJCEHD, <br />LIVE OAK GEO ENVIRONMENTAIL�, IN <br />MARCH 10, 2017 <br />SOIL SUITABILITYMITRATE LOAOING STU0jjgy2jLflNR!N2L <br />A SATISFACTORY SOIL PERCOLATION RATE OF 1 O9 MIN/IN WAS OBSERVED ATTEST <br />LOCATION. <br />THE ONSITE WELL WAS SAMPLED BY FGL ON FEBRUARY 7, 2017, WITH TEST RESULTS <br />REPORTED AS NON. -DETECT FOR NITRATES AND DBCP. <br />ma"T mam za�l <br />I STORM DRAIN NPDES PERMIT TO COMPLY WITH THE STATE OF CALIFORNIA'S <br />STATEWIDE GENERAL NPDES PERMIT, REGULATING DISCHARGES OF STORM WATER <br />ASSOCIATED WITH CONSTRUCTION ACTIVITY FROM SOIL DISTURBANCES OF ONE <br />ACRE OR MORE. A NOTICE OF INTEN-r (NOI) TO COMPLY WITH THE TERMS OF THE <br />GENERAL PERMIT TO DISCHARGE STORM WATER ASSOCIATED WITH CONSTRUCTIO <br />ACTIVITY MUST BE FILED AND THE APPROPRIATE FEE PAID PRIOR TO COMMENCEME <br />OF CONSTRUCTION. IN ADDITION, AT THE CONCLUSION OF THE PROJECT A NOTIC <br />OF TERMINATION (NOT) MUST ALSO BE FILED. SUBMIT THE FEE, NOI, AND NOT TO T" <br />STATE WATER RESOURCES CONTROL BOARD UTILIZING THE STORM WATER MULTIPL <br />APPLICATION AND REPORT TRACKING SYSTEM (SMARTS) AT THE FOLLOWING <br />ADDRESS: I <br />WWW.SMARTS,WATERBOARDS,CA,GOV <br />FEES AND PAYMENT'S CAN BE MADE TO 'THE FOLLOWING ADDRESS. <br />STATE WATER RESOURCES CONTROL BOARD <br />DIVISION OF WATER QUALITY <br />ATTN. STORM WATER PERMIT UNIT <br />BOX 1977 <br />SACRAMENTO, CA 95812-1977 <br />AVERAGE DAILY SEWAGE FLOW CALCULATIONS <br />PARAMETER CALCULATION <br />. .. . .... --- ---- <br />IF YOU HAVE ANY QUESTIONS CALL JOSEPH HENAO, WATER QUALITY CONTROL <br />SEWER FLOW RATE PER RV UNIT' 100 GPD/UNIT <br />ENGINEER, CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD, AT (916)255-3028. <br />NUMBER OF RVS X 16 <br />AVERAGE DAILY FLOW - RV 1,600 GPD <br />THE FOLLOWING MUST BE SUBMITTED TO THE COUNTY PRIOR TO BEGINNING WORK AND <br />PRIOR TO THE ISSUANCE OF AN ENCROACHMENT PERMIT: <br />RV OCCUPANCY 45 DAYS <br />REDUCTION CONVERSION 2 365 DAYS/YEAR <br />A) 'TRANSMITTAL MEMO THAT INCLUDES: <br />REDUCED AVERAGE DAILY SEWAGE FLOW- ROI'197 GPD <br />*THE NAME, AND PHONE NUMBER OF THE PERSON RESPONSIBLE FOR SWPPP <br />IMPLEMENTATION, AND <br />SEWER FLOW RATE --CLUBHOUSE BEDROOM' 140 GPD/BEDROOM <br />*IF APPLICABLE, A LISTING OF THE POST -CONSTRUCTION BEST MANAGEMENT <br />NUMBER OF BEDROOMS x 2 <br />PRACTICES THAT WILL BE INSTALLED TO SATISFY THE REQUIREMENTS OF SAN <br />AVERAGE DAILY SEWAGE FLOW - CLUBHOUSE <br />JOAQUIN COUNTY. <br />BEDROOM 280 GPD <br />*COPY OF SWPPP MUST REMAIN ON SITE DURING CONSTRUCTION AT ALL TIMES. <br />SEWER FLOW RATE --CLUBHOUSE (ANNUAL <br />B) COPY OF A SIGNED NOTICE OF INTENT FORM OR A WASTE DISCHARGE <br />ABBREVIATIONS <br />PARTY)" 5 GPD/GUEST <br />IDENTIFICATION NUMBER. <br />AB <br />AGGREGATE BASE <br />NTS <br />NOT TO SCALE <br />NUMBER OF GUESTS x 50 <br />ALT <br />ALTERNATE <br />OC <br />ON CENTER <br />AVERAGE DAILY SEWAGE FLOW - CLUBHOUSE 250 GPD <br />AVE <br />AVENUE <br />OHE <br />OVERHEAD ELECTRIC <br />OCCUPANCY X 45 DAYS <br />BFP <br />BACK FLOW PREVENTER <br />PCA <br />POINT' OF CURVATURE <br />REDUCTION CONVERSION 365 DAYS/YEAR <br />BTWN <br />BETWEEN <br />PG&E <br />PACIFIC GAS AND ELECTRIC <br />REDUCED AVERAGE DAILY SEWAGE FLOW - <br />av <br />BUTTERFLY VALVE <br />PL <br />PROPERTY LINE <br />CLUBHOUSE 31 GPD <br />CIP <br />CAST IN PLACE <br />PT <br />POINT <br />TOTAL AVERAGE DAILY FLOW, ADF <br />CMP <br />CORRUGATED METAL PIPE <br />P.T4 <br />POINT OF TANGENT <br />TOTAL REDUCED AVERAGE DAILY FLOW, RADF 508 GPD <br />CONC OR CC CONCRETE <br />R <br />RADIUS <br />'SJCEHD TABLE 6,6 (G), <br />DIA <br />DIAMETER <br />RCP <br />REINFORCED CONCRETE PIPE <br />2 LOGE STUDY TABLE 6 REDUCTION FACTOR FOR AVERAGE DAILY FLOW PER YEAR. <br />DIP <br />DUCTILE IRON PIPE <br />R.D. <br />RELETIVE DENSITY <br />'LOGE` STUDY TABLE 6 <br />EX <br />EXISTING <br />RD <br />ROAD <br />4 SJCEHD OW75 STANDARDS TABLE 6.6(S) <br />FDN <br />FOUNDATION <br />REINIF <br />REINFORCED <br />FF <br />FINISH FLOOR <br />REQ'D <br />REQUIRED <br />TANK CAPACITY" CALCULATIONS <br />FIG <br />FINISH GRADE <br />RT <br />RIGHT <br />BASE TANK CAPACITY, 37C 1,200 GALLONS <br />FH <br />FIRE HYDRANT <br />5 <br />SLOPE / SOUTH <br />AVERAGE DAILY SEWAGE FLOW 508 GALLONS <br />GPD <br />GALLONS PER DAY <br />SHT <br />SHEET <br />MINIMUM COMBINED TANK CAPACITY, CTC1,708 GALLONS <br />GR <br />GRATE <br />Sim <br />SIMILAR <br />DESIGN COMBINED TANK CAPACITY, DCTCz 2,130 GALLONS <br />GV <br />GATE VALVE <br />SS <br />SANITARY SEWER <br />SPECIFIED TANK CAPACITY 2,500 GALLONS <br />HORIZ <br />HORIZONTAL <br />SSFM <br />SANITARY SEWER FORCE MAIN <br />'BASED ON REDUCE[) RADE FOR RVS AND CLUBHOUSE. <br />HT <br />HEIGHT <br />SST <br />STAINLESS STEEL <br />"BASED ON NON -REDUCED ADF TOTALING 2,130 GALLONS. <br />ID <br />INSIDE DIAMETER <br />ST <br />STREET <br />INV <br />INVERT <br />STD <br />STANDARD <br />A 2,500 GALLON SEPTIC TANK WILL BE UTILIZED IN LIEU OF A 1,708 -GALLON CTC, TO ENSURE <br />IRR <br />IRRIGATION <br />STL <br />STEEL <br />THE SYSTEM IS CAPABLE OF HANDLING SURGE$ OF LIQUID WASTE GENERATED IN A 24-HOUR <br />PERIOD, THIS TANK CAPACITY WAS CALCULATED USING THE NON -REDUCED ADF VALUES THAT <br />LF <br />LINEAL FEET OR LINEAR FEET <br />TEMP <br />TEMPORARY <br />INDICATED 2,130 GPD OF WASTE COULD POTENTIALLY BE GENERATED DURING PEAK USES OF <br />LT <br />LEFT <br />TG <br />TOP OF GRATE <br />THE SYSTEM, AS FOLLOWS. <br />MAX <br />MAXIMUM <br />THRO <br />THROUGH <br />FILTER BED CALCULATIONS <br />MFR <br />MANUFACTURER <br />TYP <br />TYPICAL <br />SOIL FACTOR-CLAY/PEAT 0,25 <br />MGD <br />MILLION GALLONS PER DAY <br />LION <br />UNLESS OTHERWISE NOTED <br />MIN <br />MINIMUM <br />VERT <br />VERTICAL <br />Cl C x 1,708 GALLONS <br />LEACH LINE 427 LINEAL FEET <br />N <br />NORTH / NEW <br />W <br />WATER / WEST <br />MULTIPLICAl ION FACTOR FOR CLAY SOILS' x 4 FEET <br />NIC <br />NOT INCLUDED <br />wM <br />WATER METER <br />SPECIFIED TANK CAPACITY 1,708 SQUARE -FEET <br />ISJCEHD TABLE 93.2. <br />SJCEHD SECTION 9.8-1, <br />SECTION AND DETAIL NUMBERING SYSTEM <br />SECTION CUT ON PLAN <br />ENGINEERED FILL, <br />1. TWO FEET OF ENGINEERED DESIGNED FILL WILL BE IMPORTED AND BE PLACED ON'rop <br />OF EXISTING SURFACE GRADE IN THE DISPERSAL AREA OF THE OWTS. THE FILL IS <br />CA> <br />DESIGNED TO PROVIDE A FIVE-FOOT SEPARATION FROM THE BOTTOM OF THE FILTER BED <br />TO THE GROUNDWATER AND CONTAINS A HIGH CARBON CONTENT AND DENSITY TO <br />SLOW PERCOLATION FOR MICROBES TO FURTHER DENITRIFY THE EFFLUENT PRIOR TO ITS <br />MOVEMENT INTO THE SATURATED ZONE. THUS AUGMENTING THE NEED FOR AN EIGHT <br />SECTION SHOWN <br />FOOT SEPARATION FROM GROUNDWATER. <br />1 , SANITARY SEWER FORCE MAIN SHALL BE 4" A.B.$, SCHEDULE 40 AND ALL, JOINTS GLUED <br />OR SEALED ACCORDING TO ASTM STANDARDS. <br />2, SANITARY SEWER LEACH LINE SHALL BE 4" PERFORATED PVC, OR APPROVED EQUAL, ALL <br />BENDS IN LEACH LINE SHALL HAVE ONE TIGHT JOINT AT EACH END OF BEND. <br />NAME—- <br />E'SCALE- <br />DETAIL NUMBERING SYSTEM <br />7) <br />MOWN <br />1. "VAR" IN THE DRAWING DESIGNATION AREA INDICATES DETAIL APPLIES TO MORE <br />THAN ONE DRAWING, <br />2, " - " IN THE DRAWING AREA INDICATES THAT SECTION OR DETAIL IS SHOWN ON THE <br />SAME DRAWING THAT IT IS CUT FROM OR REFERRED TO, <br />