Laserfiche WebLink
SVEIGWE SYSTEM <br />FIELD MONITORING DATA SHEETS <br />e? <br />Date: U Y 1 r:7 — o3 /! o <br />Technician: Steve Thompson GN � k� <br />Site Engineer: Bob Jackson <br />f. <br />PART A: GENERAL INFORMATION <br />Time of Arrival:_ <br />Time of Departure <br />ill-Ot7 <br />Time Site Engineer was contacted from field? <br />Site Location: Chevron 9-5775, 301 West Kettleman Lane, Lodi, CA Project No. 77CH.95c7175.02.0550 <br />Abatement Equip.: Falmouth Products Falco 100 Catalytic Oxidizer Serial No.: Af'�- l 7..53/ 7 <br />SVE Blower: 5 hp motor, 15.5 Amp AMP Reading: <br />Telemetry: Sonitrol MAX AMP Rating: <br />Electrical Power: 230 V 3 phase – 200 amp <br />Elect. Meter Reading: <br />Supplemental Fuel: None <br />r-. No. of K/O barrels at site: Full Empty <br />PART B: SVE SYSTEM DATA <br />System up or down upon arrival: V, (If down please complete PART E) <br />Hourmeter Reading: 22 �- At time: Z 0D <br />A <br />Previous hourmeter reading <br />Zz365.5 <br />B <br />Current hourmeter reading <br />C <br />Current reading minus previous reading <br />D <br />Total hours since last O&M event <br />E <br />C/ D X 100 <br />100 % Operability <br />Repo percent opera l 1 y to sr a engineer error o eaWng site <br />5A -ADW ASR <br />Sni- f� Ef�C <br />CADocuments and Settings\Gary Clitl\Local Settings\Temporary Internet Files\OLK91%OMDATA Sheet.doc <br />