Laserfiche WebLink
Lancaster Laboratories <br />H Where quaalit is a scien. <br />QualMy Contcerol Summary <br />Page 2 of 2 <br />Client Name: Chevron Products Company Group Number: 802783 <br />Reported: 04/09/02 at 05:54 PH <br />Surrogate Quality Control <br />Analysis Name: TPH-GRO - Waters <br />Batch number: 02095A53A <br />Triflucrotoluene-F <br />3799923 <br />84 <br />Blank <br />85 <br />LCS <br />94 <br />MS <br />93 <br />MSD <br />91 <br />ts: 67-135 <br />Analysis Name: Methanol and Ethanol <br />Batch number: 020960019A <br />Acetone <br />3799923 <br />97 <br />Blank <br />103 <br />LCS <br />103 <br />MS <br />101 <br />MSD <br />101 <br />Limits: 72-128 <br />' ilysis Name: BTEX + Oxygenates by <br />8260B <br />.,-dtch number: V020941AB <br />Dibromofluoromethane <br />1,2-Dichloroethane-d4 <br />Toluene -d8 <br />4-Bromofluorobenzene <br />3799923 102 <br />103 <br />107 <br />105 <br />3799924 104 <br />100 <br />106 <br />107 <br />Blank 104 <br />103 <br />105 <br />103 <br />LCS 109 <br />101 <br />106 <br />106 <br />MS 108 <br />101 <br />108 <br />109 <br />MSD 108 <br />101 <br />109 <br />109 <br />Limits: 86-118 80-120 88-110 86-115 <br />*- Outside of specification <br />C) The result for one or both determinations was less than five times the LOQ. <br />/' The background result was more than four times the spike added. <br />Lancaster Laboratories, Inc. <br />MEMBER 2425 New Holland Pike <br />®PO Bax 12425 <br />Lancaster, PA 17605-2425 <br />717-656-2300 Fax: 717-656-2681 <br />2216 Rev. 9/11/00 <br />