SVE/GWE SYSTEM <br />FIELD MONITORING DATA SHEETS <br />Date. 42"' Time of Arrival: <br />Technician: _ -1 Time of Departure: <br />Site Engineer:__10c? t—, Was Site Engineer contacted from field? Yes No <br />PART A: GENERAL INFORMATION <br />Site Location: Chevron 9-5775 301 West Kettleman Lane Lodi CA Project No. 77CH.43452.00.0550 <br />Abatement Equip., Falmouth Products Falco „100 Catalytic Oxidizer Serial No.: <br />SVE Blower: 5 hip motor, 15.5 Amp <br />Telemetry: Pei .- 7Lr-G I <br />Max AMP Rating: /S 5 <br />MAX AMP Rating: <br />Electrical Power: 230 V 3 phase — 200 am <br />Supplemental Fuel: None Elect. Meter Reading: <br />No. of WO barrels at site: Full Empty <br />PART B: SVE SYSTEM DATA <br />System up or down upon arrival: (If down please complete PART E) <br />r j <br />Hourmeter Reading: ��S ! 6„ 6 . Z At time: <br />In <br />Flow Data <br />Before Adjustment <br />After Adjustment <br />Final <br />% Dilution air valve a en <br />% Recirculation valve open <br />% D �o <br />A9 <br />WO Content 1 <br />d �s <br />�� <br />Vacuum @ blower (in H2O) <br />Gauge Range <br />, <br />7 t✓� <br />�Q •�� <br />AMPS drawn by blower motor AMPS <br />Total System Flow (A P, in HZO) <br />Pipe Size <br />L�-�! <br />/ d 3. �f <br />Well Field Air Flow (A P, In H2O) <br />PI Size 4" <br />p <br />/ 2, <br />Dilution Air Flow (A P, 'H2O) <br />Pipe Size "46 <br />FID Data <br />W/ Carbon <br />W/O Carbon <br />Difference <br />tem Influent v before dilution <br />System Influent my after dilution)System <br />Effluent my <br />�—► <br />�� <br />Field Instrument Used: Last Calibrated: l OZ <br />