Laserfiche WebLink
SVEIGWE SYSTEM <br />FIELD MONITORING DATA SHEETS <br />Dale: <br />Time of Arrival <br />Technician: Steve Thom son Time of Departure: ?U <br />Site Engineer: aavid M. Evans Was Site Engineer contacted from field? Yes__ ,/ No <br />PART A: GENERAL INFORMATION <br />Site Location: Chevron 95775 301 West Kettleman Lane Lodi CA Project No. 077.43452.550 <br />Abatement Equip.: Falmouth Products Falco 100 Catalytic Oxidizer Serial No <br />SVE Blower: 5 hp motor, 15.5 Amp Max AMP Rating- <br />Telemetry: <br />atingTelemetry: MAX AMP Rating: <br />Electrical Power: 230 V 3 phase - 200 amp _ <br />Elect. Meter Reading: <br />Supplemental Fuel: None <br />No. of K/O barrels at site: _ ,D��� --Ful! Empty <br />PART B: SVE SYSTEM DATA <br />• <br />1ij <br />0 <br />System up or down upon arrival: / (If down please complete PART E) <br />Flourmeter Reading: _ [� !� %� At time: i5 �� <br />