• <br />GETTLER-RYAN INC. <br />FIELD METHODS AND PROCEDURES <br />Site Safety Plan <br />Field work performed by Gettler-Ryan Inc (GR) is conducted in accordance with GR's Health and Safety Plan and <br />the Site Safety Pian GR personnel and subcontractors who perform work at the site are briefed on the contents of <br />these plans prior to initiating site work The GR geologist or engineer at the site when the work is performed acts <br />as the Site Safety Officer GR utilizes a photoionization detector (PID) to monitor ambient conditions as part of <br />the Health and Safety Plan <br />Collection of Samples <br />Soil samples are collected from the wall or base of the excavation with a hand -driven sampling device fitted with a <br />2-mch-diameter, clean brass tube or stainless steel liner If safety considerations preclude collection of the samples <br />with the drive sampler, the excavating equipment is used to bring soil from the pit wall to the surface, where a <br />sample tube is filled by driving it into the soil in the excavator's bucket After removal from the sampling device, <br />sample tubes are covered on both ends with teflon sheeting, capped, labeled, and place in a cooler with blue ice for <br />preservation A chain -of -custody form is initiated in the field and accompanies the selected soil samples to the <br />analytical laboratory <br />If it is necessary to collect a sample of groundwater standing in the UST pit, the sample is collected by lowering a <br />new, clean teflon bailer into the pit from a safe position along the pit wall Once filled and retrieved, the <br />groundwater in the bailer is carefully decanted into the appropriate containers supplied by the analytical laboratory <br />• If required, preservative is added to the sample bottles by the laboratory prior to delivery The samples are then <br />labeled and placed in a cooler with blue ice for preservation A chain -0f -custody form is initiated in the field and <br />accompanies the selected soil samples to the analytical laboratory <br />Field Screening of Soil Samples <br />A FID is used to perform head -space analysts in the field for the presence of organic vapors from soil samples <br />This test procedure involves placing a small amount of the soil to be screened in a sealable plastic bag The bag is <br />warmed in the sun to allow organic compounds in the soil sample to volatilize The PID probe is inserted through <br />the wall of the bag and into the headspace inside, and the meter reading is recorded in the field notes An <br />alternative method involves placing a plastic cap over the end of the sample tube The PID probe is placed through <br />a hole in the plastic cap, and vapors with the covered tube measured Head -space screening is performed and <br />results recorded as reconnaissance data only GR does not consider field screening techniques to be verification of <br />the presence or absence of hydrocarbons <br />Storing and Sampling of Soil Stockpiles <br />Excavated material is stockpiled on and covered with plastic sheeting Stockpile samples are collected and <br />analyzed for disposal classification on the basis of one composite sample per 100 cubic yards of soil Stockpile <br />samples are composed of four discrete soil samples, each collected from an arbitrary location on the stockpile The <br />four discrete samples are then composited in the laboratory prior to analysis <br />Each discrete stockpile sample is collected by removing the upper 12 to 18 inches of soil, and then driving the <br />stainless steel or brass sample tube into the stockpiled material with a mallet or drive sampler The sample tubes <br />are then covered on both ends with teflon sheeting, capped, labeled, and placed in a cooler with blue ice for <br />. preservation A chain -of -custody form is initiated in the field and accompanies the selected soil samples to the <br />analytical laboratory Stockpiled soils are covered with plastic sheeting after completion of sampling <br />346408 02 <br />