My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STIMSON
>
2000
>
2800 - Aboveground Petroleum Storage Program
>
PR0516339
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2019 2:50:17 PM
Creation date
10/10/2018 9:53:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516339
PE
2832
FACILITY_ID
FA0003648
FACILITY_NAME
STKN ARMY AVIATION SUPP FACILITY*
STREET_NUMBER
2000
STREET_NAME
STIMSON
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17726004
CURRENT_STATUS
01
SITE_LOCATION
2000 STIMSON RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monday, October 25, 2004 <br />Tank Team Incorporated. <br />2745 Sherwin Ave., Unit B <br />Ventura, CA 93003-7241 <br />Attention: Bernie Olson, Project Manager <br />Subject: Structural Integrity Inspection and Report <br />One (1) 20,000 Gallon Aboveground Storage Tank (AST) <br />California Army National Guard, Stockton, CA <br />Dear Mr. Olson, <br />On October 25`h, 2004, Corrosion Specialists, Inc. performed a baseline structural integrity <br />inspection. This survey was conducted on the external steel surfaces of the aboveground <br />storage tank. The tank is a 20,000 Jet Fuel JP8, and is located at the California Army National <br />Guard in Stockton, CA. <br />FINDINGS AND CONCLUSIONS <br />1. All Ultrasonic Thickness (UT) measurements were obtained using a Panametrics 37DL <br />PLUS. All readings recorded are found to be greater than 75% of the original wall <br />thickness. Our instrument was calibrated prior to each use and the thicknesses obtained <br />were accurate. <br />2. All UT readings were acquired through the tank exterior coating system, demonstrating <br />good adherence of the tanks exterior systems to the substrate or tank exterior wall. <br />Should there have been voids, discontinuities or disbonding of the tanks coating <br />systems, obtaining these readings would not have been possible. <br />3. Since the information in this report provides baseline data, all readings obtained and <br />recorded should be compared when obtaining future readings and to determine losses, <br />if any. <br />P,0. Box 787, Pinofp, CA, 945-64 K Ph,.: ,(510,) 867-07081"c: x (51' ) 756-7172 <br />
The URL can be used to link to this page
Your browser does not support the video tag.