San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />711 MATERIALS <br />2714 STAGECOACH RD STOCKTON <br />February 09 2016 <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />725 <br />CFR 112.8(d)(3) <br />Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction <br />❑ V ❑ R ❑ COS <br />726 <br />CFR 112.8(d)(4) <br />Failed to regularly inspect aboveground valves, piping, and appurtenances <br />❑ V ❑ R ❑ COS <br />727 <br />CFR 112.8(d)(4) <br />Failed to conduct integrity and leak test on buried piping any time it is worked on <br />❑ V ❑ R ❑ COS <br />728 <br />CFR 112.8(d)(5) <br />Failed to adequately warn vehicles entering facility to protect piping and other transfer operations <br />❑ V ❑ R ❑ COS <br />Other Violations <br />4010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R r:i COS <br />4020 <br />See below <br />Unlisted Training violation <br />❑ V ❑ R ❑ COS <br />4030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />4040 <br />See below <br />Unlisted Release/Leaks/Spills violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />604 <br />CFR 112.7(a)(3) No facility diagram or didn't show location and contents of containers, transfer stations, and pipes. <br />The facility map was incomplete and did not include piping and the location of each tank. The Spill Prevention, <br />Control, and Countermeasure (SPCC) Plan shall include a facility diagram which must mark the location and contents <br />of each fixed storage container and the storage area where mobile or portable containers are located. It must identify <br />the location of and mark as "exempt" underground tanks. It must also include all transfer stations and connecting <br />pipes, including intra-facility gathering lines. Immediately update the facility diagram to include all of the required <br />information. Submit a legible copy of the updated facility diagram to the EHD for review. <br />This is a repeat violation, Class II. <br />609 <br />CFR 112.7(c) Failed to provide secondary containment, diversionary structures, or equipment to prevent discharge. <br />SPCC Plan stated that the 55 gallon drums had "limited' secondary containment. The drums were observed without <br />containment capable of holding 55 gallons. The SPCC plan stated the used oil tank had "partial' secondary <br />containment and the secondary containment did not have the capacity to hold the full contents. A facility shall provide <br />appropriate containment and/or diversionary structures or equipment to prevent a discharge. The entire containment <br />system, including walls and floor, must be capable of containing oil and must be constructed so that any discharge <br />from a primary containment system will not escape the containment system before cleanup occurs. Immediately <br />provide adequate secondary containment for all aboveground petroleum storage containers larger than 55 gallons. <br />This is a repeat violation, Class II. <br />706 <br />CFR 112.8(c)(2) Failed to provide and maintain adequate secondary containment. <br />SPCC Plan stated that the 55 gallon drums had "limited' secondary containment. The drums were observed without <br />containment capable of holding 55 gallons. The SPCC plan stated the used oil tank had "partiar' secondary <br />containment and the secondary containment did not have the capacity to hold the full contents. All bulk storage tanks <br />must be provided with a secondary means of containment for the entire capacity of the tank and sufficient freeboard to <br />contain precipitation. Immediately provide sufficient secondary containment for this and all other tanks at this facility. <br />This is a repeat violation, Class II. <br />Page 3 of 5 <br />