My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
22888
>
2800 - Aboveground Petroleum Storage Program
>
PR0515878
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/5/2019 4:51:46 PM
Creation date
10/10/2018 1:59:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0515878
PE
2834
FACILITY_ID
FA0003821
FACILITY_NAME
CHEVRON PRODUCTS COMPANY #1001621
STREET_NUMBER
22888
Direction
S
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
22888 S KASSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
699
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAOUIN <br />C 0 UJ -]I <br />Environmental Health Department <br />MENDED <br />FA0003821 PRO515878 SCO01 01114/2016 <br />EHD 28-01 Rev. 11/07/2017 Page 3 of 5 Aboveground Petroleum Storage Act OIR <br />1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />CHEVRON PRODUCTS COMPANY #1001621 <br />Facility Address: <br />22888 S KASSON RD. TRACY <br />Date: <br />January 14, 2016 <br />General Requirements for SPCC Plans <br />630 <br />CFR 112.7(k) <br />Failure to provide general secondary containment or alternative for oil -filled operational equipment <br />c V <br />❑ R <br />❑ COS <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />701 <br />CFR 112.8(b)(1) <br />Failure to ensure drainage from diked areas is restrained by valves or alternative method <br />❑ V <br />❑ R <br />o COS <br />702 <br />CFR 112.8(b)(2) <br />Failed to use manual open -and -closed design valves for the drainage of diked areas <br />❑ V <br />o R <br />o COS <br />703 <br />CFR 112.8(b)(3), <br />112.8(b)(4) <br />Failed to design facility drainage system from undiked areas to retain in the facility <br />o V <br />❑ R <br />o COS <br />704 <br />CFR 112.8(b)(5) <br />Failed to provide two lift pumps for more than one continuous treatment unit <br />❑ V <br />o R <br />a COS <br />705 <br />CFR 112.8(c)(1) <br />Container not compatible with oil stored and/or storage conditions <br />❑ V <br />o R <br />o COS <br />706 <br />CFR 112.8(c)(2) <br />Failed to provide and maintain adequate secondary containment <br />❑ V <br />❑ R <br />o COS <br />707 <br />CFR 112.8(c)(3) <br />Failure to follow the criteria of this section while allowing drainage of uncontaminated rainwater <br />❑ V <br />❑ R <br />❑ COS <br />708 <br />CFR 112.8(c)(3)(iv) <br />Failed to maintain records of drainage from diked areas <br />o V <br />❑ R <br />❑ COS <br />709 <br />CFR 112.8(c)(3)(iii) <br />Failed to open and close bypass valve to drain rainwater under responsible supervision <br />❑ V <br />❑ R <br />o COS <br />710 <br />CFR 112.8(c)(6) <br />Plan failed to adequately discuss procedures to test or inspect each container for integrity <br />❑ V <br />❑ R <br />❑ COS <br />711 <br />CFR 112.8(c)(6) <br />Failed to perform scheduled tank tests or inspections by appropriately qualified personnel <br />■ V <br />❑ R <br />o COS <br />712 <br />CFR 112.8(c)(6) <br />Failed to test or inspect each container for integrity based on industry standards <br />❑ V <br />c R <br />o COS <br />713 <br />CFR 112.8(c)(7) <br />Failed to provide effective leakage control from defective internal heating coils <br />o V <br />o R <br />o COS <br />714 <br />CFR 112.8(c)(8)(i-iv) <br />Failed to provide each container with a high level monitoring device <br />o V <br />❑ R <br />o COS <br />715 <br />CFR 112.8(c)(8)(v) <br />Failed to regularly test liquid level sensing devices to ensure proper operation <br />❑ V <br />o R <br />o COS <br />716 <br />CFR 112.8(c)(9) <br />Failed to observe effluent treatment frequently enough to detect potential discharge <br />❑ V <br />❑ R <br />o COS <br />717 <br />j CFR 112.8(c)(10) <br />Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas <br />o V <br />❑ R <br />❑ COS <br />718 <br />CFR 112.8(.)(11) <br />Failed to locate properly or provide sufficient secondary containment for mobile/portable containers <br />❑ V <br />❑ R <br />o COS <br />719 <br />CFR 112.8(d)(1) <br />Failed to take corrective action on buried piping when exposed for any reason <br />❑ V <br />❑ R <br />o COS <br />720 <br />CFR 112.8(d)(1) <br />Failed to provide corrosion protection for buried piping <br />❑ V <br />❑ R <br />❑ COS <br />721 <br />CFR 112.8(d)(2) <br />Failed to cap/blank-flange connection at transfer point and mark its origin if not in service <br />❑ V <br />o R <br />❑ COS <br />722 <br />CFR 112.8(d)(3) <br />Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction <br />o V <br />❑ R <br />❑ COS <br />723 <br />CFR 112.8(d)(4) <br />Failed to regularly inspect aboveground valves, piping, and appurtenances <br />o V <br />❑ R <br />❑ COS <br />724 <br />CFR 112.8(d)(4) <br />Failed to conduct integrity and leak testing on buried piping any time it is worked on <br />o V <br />❑ R <br />o COS <br />725 <br />CFR 112.8(d)(5) <br />Failed to adequately warn vehicles entering facility to protect piping and other transfer operations <br />o V <br />❑ R <br />❑ COS <br />Other Violations <br />4010 <br />See below <br />Unlisted Administration/Documentation violation <br />o V <br />❑ R <br />❑ COS <br />4020 <br />See below <br />Unlisted Training violation <br />o V <br />❑ R <br />o COS <br />4030 <br />See below <br />Unlisted Operations/Maintenance violation <br />o V <br />❑ R <br />❑ COS <br />4040 <br />See below <br />Unlisted Release/Leaks/Spills violation <br />o V <br />❑ R <br />o COS <br />4050 <br />See below <br />Unlisted Abandonment lllegal Disposal/Unauthorized Treatment violation <br />❑ V <br />o R <br />❑ COS <br />FA0003821 PRO515878 SCO01 01114/2016 <br />EHD 28-01 Rev. 11/07/2017 Page 3 of 5 Aboveground Petroleum Storage Act OIR <br />1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.