My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
700
>
2800 - Aboveground Petroleum Storage Program
>
PR0527961
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 8:52:51 AM
Creation date
10/10/2018 3:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0527961
PE
2832
FACILITY_ID
FA0018952
FACILITY_NAME
AAFES WEST COAST DISTRIB CENTER
STREET_NUMBER
700
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
LATHROP
Zip
95231-9735
APN
19802001
CURRENT_STATUS
01
SITE_LOCATION
700 E ROTH RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOHUIN <br />- i_ <br />Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />AAFES WEST COAST DISTRIB CENTER <br />Facility Address: <br />700 E ROTH RD, LATHROP <br />Date: <br />July 12, 2018 <br />Other Violations <br />4050 1 <br />See below <br />Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS Il, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />201 <br />CFR 112.3(d) Failure to have a licensed PE properly review and certify the SPCC plan. <br />The Professional Engineer (PE) certification is incomplete. The SPCC plan is missing the signature, date and stap <br />of the PE. The PE certification must include all of the aspects in 40 CFR 112.3(d)(1), including attesting that the PE <br />is familiar with 40 CFR Part 112, he or his agent has visited and examined the facility, the Spill Prevention, Control, <br />and Countermeasure (SPCC) Plan has been prepared in accordance with good engineering practice, including <br />consideration of applicable industry standards, procedures have been established for required inspections and <br />testing, and the Plan is adequate for the facility. Immediately obtain a complete PE certification for the facility's <br />SPCC Plan. Submit a copy of the completed certification to the EHD. <br />This is a Class II violation. <br />603 <br />CFR 112.7(a)(3) Failed to adequately describe the physical layout of the facility in the Plan. <br />A facility diagram was not included in the SPCC plan. The Spill Prevention, Control, and Countermeasure (SPCC) <br />Plan shall include a facility diagram which must mark the location and contents of each fixed storage container and <br />the storage area where mobile or portable containers are located. It must identify the location of and mark as <br />"exempt" underground tanks. It must also include all transfer stations and connecting pipes, including intra -facility <br />gathering lines. Immediately update the facility diagram to include all of the required information. Submit a legible <br />copy of the updated facility diagram to the EHD for review. <br />This is a Class II violation. <br />618 <br />CFR 112.7(e), 112.8(c)(6) Failed to keep records of procedures, inspections, or integrity tests for three years. <br />Copies of inspection and testing records for were not found on site. Inspections and tests must be conducted in <br />accordance with the written procedures developed in the Spill Prevention, Control, and Countermeasure (SPCC) <br />Plan. Records of these inspections and tests must be signed by the appropriate supervisor or inspector and kept on <br />site with the SPCC Plan for a period of three years. Immediately locate a copy of all inspection and testing records <br />for the last three years, maintain them on site, and submit copies to the EHD. <br />This is a Class II violation. <br />619 <br />CFR 112.7(f)(1) Failed to train personnel on all discharge prevention details listed in this section. <br />Oil handling personnel were not trained. At a minimum, oil handling personnel shall be trained in the operation and <br />maintenance of equipment to prevent discharges; discharge procedure protocols; applicable pollution control laws, <br />rules, and regulations; general facility operations; and the contents of the Spill Prevention, Control, and <br />Countermeasure Plan. Immediately provide this training to all oil handling personnel. <br />This is a Class II violation. <br />FA0018952 PRO527961 SCO01 07/12/2018 <br />EHD 28-01 Rev. 11/07/2017 Page 4 of 6 Aboveground Petroleum Storage Act OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.