Laserfiche WebLink
San Joaquin County A <br /> Environmental Health Department 2 <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.s'gov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CALAMCO 12323W PORT RD, STOCKTON July 11, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS Il, or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 605 CFR 112.7(a)(3) Plan failed to address facility layout, operations discharge prevention methods and containers. <br /> The SPCC Plan did not discuss discharge prevention measures and discharge or drainage controls for the <br /> generators and compressors at the facility. The descriptions of secondary containment structures for the other tanks <br /> on site did not include the size of the containments or any indication that they were adequately sized. The following <br /> shall be addressed in the Spill Prevention, Control, and Countermeasure(SPCC) Plan: <br /> -type of oil in each fixed container and it's storage capacity. For mobile or potable containers, the type of oil and <br /> storage capacity for each container or an estimate of the potential number of mobile or portable containers, the types <br /> of oil, and anticipated storage capacities <br /> -discharge prevention measures including procedures for routine handling of products <br /> -discharge or drainage controls such as secondary containment, equipment, and procedures for the control of a <br /> discharge <br /> -countermeasures for discharge discovery, response, and cleanup <br /> - methods of disposal of recovered materials <br /> -contact list and phone numbers for the facility response coordinator, National Response Center, cleanup <br /> contractors, and all appropriate Federal, State, and local agencies. <br /> Immediately amend the SPCC Plan to include all required information. <br /> This is a Class II violation. <br /> 609 CFR 112.7(c) Failed to provide secondary containment, diversionary structures, or equipment to prevent discharge. <br /> Secondary containment was not provided for two of the compressors and one of the generators. A facility shall <br /> provide appropriate containment and/or diversionary structures or equipment to prevent a discharge. The entire <br /> containment system, including walls and floor, must be capable of containing oil and must be constructed so that any <br /> discharge from a primary containment system will not escape the containment system before cleanup occurs. <br /> Immediately provide adequate secondary containment for all aboveground petroleum storage containers larger than <br /> 55 gallons. <br /> This is a Class II violation. <br /> Page 4 of 8 <br />