My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
8115
>
2800 - Aboveground Petroleum Storage Program
>
PR0516364
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2019 2:33:37 PM
Creation date
10/11/2018 1:31:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516364
PE
2831
FACILITY_ID
FA0000110
FACILITY_NAME
J & L MARKET
STREET_NUMBER
8115
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
FRENCH CAMP
Zip
95231
APN
19317003
CURRENT_STATUS
01
SITE_LOCATION
8115 S EL DORADO ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd <br /> Aboveground Petroleum Storage Act Qualified Facility Inspection Report <br /> Facility Name: Facility Address: Date: <br /> J & L MARKET 8115 S EL DORADO ST FRENCH CAMP May 26 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 701 CFR 112.8(b)(2) Failed to use manual open-and-closed design valves for the drainage of diked areas. <br /> The drain pipe on the secondary containment for the diesel tank is not the closing type, allowing discharges to be <br /> released immediately. Manual, open-and-closed designed valves shall be used for the drainage of diked areas. <br /> Immediately install the correct type of valves to be used for the drainage of diked areas and amend the SPCC Plan as <br /> necessary, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 704 CFR 112.8(c)(2) Diked area is not sufficiently impervious to contain discharged oil. <br /> The diesel tank secondary containment has an open drain pipe and is currently not impervious to contain discharged <br /> oil. Diked areas must be sufficiently impervious to contain discharged oil. Immediately provide or repair all diked <br /> areas to be sufficiently impervious to contain oil. <br /> This is a Class II violation. <br /> 706 CFR 112.8(c)(2) Failed to provide and maintain adequate secondary containment. <br /> The 10,000 gallon diesel tank was observed with insufficient secondary containment. The drain pipe on the secondary <br /> containment for the diesel tank is not the closing type, allowing discharges to be released immediately. No <br /> descriptions or calculations were observed indicating that the secondary containment structure contains sufficient <br /> capacity for the full contents of the tank plus freeboard for rainwater. All bulk storage tanks must be provided with a <br /> secondary means of containment for the entire capacity of the tank and sufficient freeboard to contain precipitation. <br /> Immediately provide sufficient secondary containment for this and all other tanks at this facility. <br /> This is a Class II violation. <br /> 707 CFR 112.8(c)(3)(i) Failed to keep containment bypass valves closed when not draining rainwater. <br /> The drain pipe on the secondary containment for the diesel tank is not the closing type, allowing discharges to be <br /> released immediately. Bypass valves that allow drainage of uncontaminated rainwater from the diked area into a <br /> storm drain or discharge of an effluent into an open watercourse, lake, or pond, bypassing the facility treatment shall <br /> be kept closed and sealed. Immediately close all containment bypass valves when not draining rainwater, or provide <br /> equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 708 CFR 112.8(c)(3)(ii) Failed to inspect retained rainwater prior to discharge. <br /> The drain pipe on the secondary containment for the diesel tank is not the closing type, allowing discharges to be <br /> released immediately. The rainwater discharge log in the SPCC Plan was blank. Retained rainwater from a diked <br /> area shall be inspected prior to being discharged. Ensure that rainwater is inspected prior to being discharged from <br /> diked areas, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Page 6 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.