My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
301
>
2300 - Underground Storage Tank Program
>
PR0231345
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2021 1:00:51 PM
Creation date
10/11/2018 2:24:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231345
PE
2381
FACILITY_ID
FA0003713
FACILITY_NAME
CHEVRON #95775 MCCOMBS* (INACT)
STREET_NUMBER
301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04514002
CURRENT_STATUS
02
SITE_LOCATION
301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br />U/+fns <br />STATE WATER RESOURCES CONTROL BOARD <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B W At s <br />COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM <br />MARK ONLY ❑ 1 NEW PERMIT 3 RENEWAL PERMIT In 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br />ONE ITEM ❑ 2 INTERIM PERMIT 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED: �;,-�.N S7 i s <br />I. TANK DESCRIPTION COMPLETE ALL ITEMS - SPECIFY IF UNKNOWN <br />A. OWNER'S TANK I. D. <br />B.C.❑ <br />I B. MANUFACTURED BY: <br />❑4 <br />2 PETROLEUM ❑ 80 EMPTY <br />C. DATE INSTALLED (MO/DAY/YEAR) <br />f <br />D. TANK CAPACITY IN GALLONS: <br />r c <br />ILTANKCONTENTS IFA -1 IS MARKED. COMPLETE ITEM C. <br />A. ❑ 1 MOTOR VEHICLE FUEL 4 OIL <br />B.C.❑ <br />la REGUG LAR 3 DIESEL ❑ 6 AVIATION GAS <br />❑4 <br />2 PETROLEUM ❑ 80 EMPTY <br />❑ 1 PRODUCT <br />GASAHOL <br />❑ 1b PREMIUM ❑ ❑ 7 METHANOL <br />UNLEADED ❑ 5 JET FUEL <br />❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN <br />2 WASTE <br />❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.1) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C. A. S. # <br />III. TANK CONSTRUCTION MARK ONF ITEM ONLY IN ROXFS A. R. AND C AND ALL THAT APPLIES IN BOX D AND F <br />A. TYPE OF <br />❑ 1 DOUBLE WALL <br />F—, 3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />SYSTEM <br />2 SINGLE WALL <br />❑ 4 SECONDARY CONTAINMENT <br />(VAULTED TANK) <br />❑ 99 OTHER <br />1 SINGLE WALL <br />❑ 1 BARE STEEL <br />❑ 2 STAINLESS STEEL <br />lz 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM <br />❑ 8 100% METHANOL COMPATIBLE W/FRP <br />(Primary Tank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />❑ 1 <br />1 RUBBER LINED <br />❑ 2 ALKYD LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />❑ 5 GLASS LINING <br />1 6 UNLINED <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />LINING <br />IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? <br />YES _ NO <br />D. CORROSION <br />❑ 1 POLYETHYLENE WRAP <br />7- 2 COATING <br />❑ 3 VINYL WRAP <br />4 FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />❑ 5 CATHODIC PROTECTION <br />❑ 91 NONE <br />❑ 95 UNKNOWN <br />1:1 99 OTHER <br />E. SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED (YEAR) <br />OVERFILL PREVENTION EQUIPMENT INSTALLED (YEAR) <br />IV. PIPING INFORMATION CIRCLE A IFABOVEGROUND OR U IF UNDERGROUND, BOTH IF APPLICABLE <br />A. SYSTEM TYPE <br />A U <br />1 SUCTION <br />A U <br />2 PRESSURE <br />An <br />3 GRAVITY A U 99 OTHER <br />B. CONSTRUCTION <br />A <br />1 SINGLE WALL <br />A U <br />2 DOUBLE WALL <br />A U <br />3 LINED TRENCH A U 95 UNKNOWN <br />A U 99 OTHER <br />C. MATERIAL AND <br />CORROSION <br />PROTECTION <br />A U <br />A U <br />A U <br />1 BARE STEEL <br />5 ALUMINUM <br />9 GALVANIZED STEEL <br />A U <br />A U <br />A U <br />2 STAINLESS STEEL A U <br />6 CONCRETE A U <br />10 CATHODIC PROTECTION <br />3 POLYVINYL CHLORIDE (PVC) A IV <br />7 STEEL W/ COATING A U <br />A U 95 UNKNOWN A U <br />4 FIBERGLASS PIPE <br />8 1009/6 METHANOL COMPATIBLE W/FRP <br />99 OTHER <br />D. LEAK DETECTION <br />❑ 1 <br />AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING ❑ 3 IMONfTORING A <br />rl—J] 99 OTHER <br />V. TANK LEAK DETECTION <br />1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORINC <br />}� 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION <br />1. ESTIMATED DATE LAST USED (MO/DAY/YR) 2. ESTIMATED QUANTITY OF <br />SUBSTANCE REMAININ� <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND <br />APPLICANTS NAME <br />(PRINTED 8 SIGNATURE) <br />LOCAL AGENCY USE ONLY THE STATE I.D. NUMBER IS COMPOSED OF THE FOUR <br />3. VV4S TANK FILLED WITH <br />GALLONS NER ATERIAL? YES I❑ NO ❑ <br />�EfF O M.Y K LEDGE, IS TRUE AND CORRECT <br />I <br />DATE <br />�2-r7 <br />RS BELOW <br />COUNTY 4 JURISDICTION # F4CILITY# TANK # <br />STATE I.D.# o <br />'ERMITNUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br />)RM B (7-911 THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION • FORM A, UNLESS A CURRENT FORM A HAS BEEN fjLED. / <br />FOR8034B•RS <br />
The URL can be used to link to this page
Your browser does not support the video tag.