BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
301
>
2300 - Underground Storage Tank Program
>
PR0231345
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2021 1:00:51 PM
Creation date
10/11/2018 2:24:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231345
PE
2381
FACILITY_ID
FA0003713
FACILITY_NAME
CHEVRON #95775 MCCOMBS* (INACT)
STREET_NUMBER
301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04514002
CURRENT_STATUS
02
SITE_LOCATION
301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNi, WATER RESOURCES CONTRC.. .OARD ••' { <br />FORM'B': UNDERGROUND STORAGE TANK PROGRAM #95775C <br />TANK TANK PERMIT APPLICATION INFORMATION <br />COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br />MARK ONLY ❑ 1 NEW PERMIT © 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br />ONE ITEM F-12 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE L❑ 8 TANK REMOVED <br />FACILITY/SITE NAME WHERE TANK IS INSTALLED: R.J. McComb Chevron FARM TANK - YES ❑ NO <br />I. TANK DESCRIPTION COMPLETE ALL ITEMS - IF UNKNOWN — SO SPECIFY <br />A OWNERS TANK ID # WC5715C B. MANUFACTURED BY: XERX <br />C. YEAR INSTALLED 1983 D TANK CAPACITY IN GALLONS. 10,000 gallons <br />II. TANK CONTENTS IF (A.1), IS MARKED, COMPLETE ITEM C. IF (A.1), IS NOT MARKED, COMPLETE ITEM D. <br />A 0 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM <br />B. <br />C ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br />L❑ 3 CHEMICAL PRODUCT ❑ 4 OIL <br />O 1 PRODUCT <br />❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br />❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 7 METHANOL ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D IF NOT MOTOR VEHICLE FUEL, ENTER NAME OF <br />HAZARDOUS SUBSTANCE STORED & C.A.S. # C.A S q 8006619 <br />III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A, B, C, i D <br />A. TYPE OF <br />❑ 1 DOUBLE WALLED <br />❑ 3 SINGLE WALLED WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />SYSTEM <br />X❑ 2 SINGLE WALLED <br />❑ 4 SECONDARY CONTAINMENT <br />❑ 99 OTHER <br />B. CONSTRUCTION <br />❑ 1 STEEUIRON <br />❑ 2 STAINLESS STEEL <br />® 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 1 ALUMINUM <br />❑ 8 1W% METHANOL COMPATIBLE FRP <br />MATERIAL <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />FIBERGLASS PIPE A U 91 NONE <br />❑ 1 RUBBER LINED <br />❑ 2 ALKYD LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />LINING <br />❑ 5 GLASS LINING <br />}( 6 UNLINED <br />8 100% METHANOL COMPATIBLE FRP <br />❑ 95 UNKNOWN <br />A <br />❑ IS LINING MATERIAL COMPATIBLE WITH 100% METHANOLS <br />❑ YES ❑ NO <br />❑ 99 OTHER <br />D. CORROSION <br />❑ 1 POLYETHLENE WRAP <br />❑ 2 TAR OR ASPHALT <br />�❑ 3 VINYL WRAP <br />❑ 4 FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />❑ 5 CATHODIC PROTECTION <br />❑ 91 NONE <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. SYSTEM TYPE <br />A <br />U 1 SUCTION <br />A U <br />2 PRESSURE <br />A <br />U 3 GRAVITY A U 91 NONE <br />A U 95 UNKNOWN A U 99 OTHER <br />B. CONSTRUCTION <br />AO <br />1 SINGLE WALLED <br />A <br />U 2 DOUBLE WALLED <br />A <br />U 3 LINED TRENCH A U 91 NONE <br />A U 95 UNKNOWN A U 99 OTHER <br />A <br />U 1 STEEL/IRON <br />A <br />U 2 STAINLESS STEEL <br />A <br />U 3 POLYVINYL CHLORIDE (PVC) A U4 <br />FIBERGLASS PIPE A U 91 NONE <br />C. MATERIAL <br />A <br />U 5 ALUMINUM <br />A <br />U 6 CONCRETE <br />A <br />U 7 STEEL CLAD W/FRP A U <br />8 100% METHANOL COMPATIBLE FRP <br />A <br />U 9 GALVANIZED STEEL A <br />U 95 UNKNOWN <br />A <br />U 99 OTHER <br />V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY, OR S FOR SECONDARY, A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br />P S 1 VISUAL CHECK P® 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br />S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br />VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br />1 ESTIMATED DATE LAST USED (MO/YR) 2 ESTIMATED QUANTITY OFGALLONB 3 WAS TANK FILLED WITH <br />SUBSTANCE REMAINING IN INERT MATERIAL? E]YES E]NO <br />THIS FORM HAS BEEN COMPLETED UNDER PENAL4 OF P URY, O THE B ,Y F MY KNOWLEDGE, IS TRUE AND CORRECT. <br />APPLICANT'S NAME (PRINTED 6 SIGNATURE) DATE <br />I nrAl Ar_FueV 1I4ZF nrll v <br />COUNTY N <br />E= <br />JURISDICTION M <br />AGENCY M FACILITY IDN TANK ID N <br />CURRENT LOCAL AGENCY FACILITY ID N <br />APPROVED BY NAME PHONE M WITH AREA CODE <br />PERMIT NUMBER <br />PERMIT APPROVAL DATE <br />PERMIT EXPIRATION DATE <br />- <br />CHECK# <br />PERMIT AMOUNT <br />SURCHARGE AMT.FEE CODE <br />I <br />RECEIPT I <br />BY: <br />FORM B (6-29-88) THIS FORM MUST M ACCOWAW \ FACILMMW ANRJCATKIK, FUKM -A-, UNLESS A FM'A' NAS BEEN FILED <br />1 DATA PROCESSING COPY 2 LOCAL AGENCY COPT � COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.