My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
301
>
2300 - Underground Storage Tank Program
>
PR0231345
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2021 1:00:51 PM
Creation date
10/11/2018 2:24:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231345
PE
2381
FACILITY_ID
FA0003713
FACILITY_NAME
CHEVRON #95775 MCCOMBS* (INACT)
STREET_NUMBER
301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04514002
CURRENT_STATUS
02
SITE_LOCATION
301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFIORNif WATER RESOURCES CONTRO&ARD <br />FORM 'S': UNDERGROUND STORAGE TANK PROGRAM #95775A <br />TANK TANK PERMIT APPLICATION INFORMATION <br />COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br />MARK ONLY ❑ 1 NEW PERMIT © 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br />ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br />FACILITY/SITE NAME WHERE TANK IS INSTALLED: R.J. McComb Chevron FARM TANK - YES ❑ NO ❑ <br />I. TANK DESCRIPTION COMPLETE ALL ITEMS - IF UNKNOWN - SO SPECIFY <br />A. OWNERS TANK ID 4 WC5715C B. MANUFACTURED BY: XERX <br />C. YEAR INSTALLED 1983 D TANK CAPACITY IN GALLONS: <br />11. TANK CONTENTS IF (A.1), IS MARKED, COMPLETE ITEM C. IF (A.1), IS NOT MARKED, COMPLETE ITEM D. <br />A © 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM <br />B. <br />C. a 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br />�❑ 3 CHEMICAL PRODUCT ❑ 4 OIL <br />❑ 1 PRODUCT <br />❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br />❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 7 METHANOL ❑ 99 OTHER (DESCRIBE IN ITEM D, BELOW) <br />D IF NOT MOTOR VEHICLE FUEL, ENTER NAME OF <br />HAZARDOUS SUBSTANCE STORED & C.A.S. # C.A.S. N: 8006619 <br />111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A, B, C, A D <br />A. TYPE OF <br />❑ 1 DOUBLE WALLED <br />❑ 3 SINGLE WALLED WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />SYSTEM <br />❑X 2 SINGLE WALLED <br />❑ 4 SECONDARY CONTAINMENT <br />❑ 99 OTHER <br />B. CONSTRUCTION <br />❑ 1 STEEL/IRON <br />❑ 2 STAINLESS STEEL <br />LJ 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 7 ALUMINUM <br />❑ 8 100% METHANOL COMPATIBLE FRP <br />MATERIAL <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />PIPE A U 91 NONE <br />F--]1 RUBBER LINED <br />❑ 2 ALKYD LINING <br />F-]3 EPDXY LINING <br />F-]4 PHENOLIC LINING <br />C. INTERIOR <br />LINING <br />❑ 5 GLASS LINING <br />❑ 6 UNLINED <br />8 100% METHANOL COMPATIBLE FRP <br />❑ 95 UNKNOWN <br />A <br />❑ IS LINING MATERIAL COMPATIBLE <br />WITH 100%METHANOL? <br />❑ YES ❑ NO <br />❑ 99 OTHER <br />D. CORROSION <br />❑ 1 POLYETHLENE WRAP <br />❑ 2 TAR OR ASPHALT <br />❑ 3 VINYL WRAP <br />❑ 4 FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />❑ 5 CATHODIC PROTECTION <br />❑X 91 NONE <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND, BOTH IF APPLICABLE <br />A SYSTEM TYPE <br />A <br />U 1 SUCTION <br />A U <br />2 PRESSURE <br />A U <br />3 GRAVITY A U 91 NONE <br />A U 95 UNKNOWN A U 99 OTHER <br />B. CONSTRUCTION <br />A <br />OU 1 SINGLE WALLED <br />A <br />U 2 DOUBLE WALLED <br />A U <br />3 LINED TRENCH A U 91 NONE <br />A U 95 UNKNOWN A U 99 OTHER <br />BY: <br />A <br />U 1 STEEL/IRON <br />A <br />U 2 STAINLESS STEEL <br />A U <br />3 POLYVINYL CHLORIDE (PVC) A UTII.ERGISS <br />PIPE A U 91 NONE <br />C. MATERIAL <br />A <br />U 5 ALUMINUM <br />A <br />U 6 CONCRETE <br />A U <br />7 STEEL CLAD W/FRP A U <br />8 100% METHANOL COMPATIBLE FRP <br />A <br />U 9 GALVANIZED STEEL A <br />U 95 UNKNOWN <br />A U <br />99 OTHER <br />V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY, OR S FOR SECONDARY, A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br />P 8 1 VISUAL CHECK P 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br />8 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br />VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br />I. ESTIMATED DATE LAST USED (MO/YR) 2 ESTIMATED QUANTITY OF GALLONS 3. WAS TANK FILLED WITH <br />SUBSTANCE REMAINING IN INERT MATERIAL? ❑ YES ❑ NO <br />THIS F( <br />a AN Ai <br />3M HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BES OF`MY KNOWLEDGE, IS TRUE AND C( <br />APPLICANT'S NAME (PRINTED& SIGNATURE) 1 j l / I DATE <br />G - D& <br />AV1I <br />- Jori So V3 <br />runv I Ic�r nus v i <br />4RECT. <br />[CTOUNTY# <br />JURISDICTION M <br />AGENCY N FACILITY ID M TANK ID N <br />J I I I I I I I <br />CURRENT LOCAL AGENCY FACILITY ID t <br />APPROVED BY NAME PHONE 0 WITH AREA CODE <br />PERMIT NUMBER <br />PERMIT APPROVAL DATE <br />PERMIT EXPIRATION DATE <br />CHECK • <br />PERMIT AMOUNT <br />SURCHARGE AMT. <br />FEE CODE <br />RECEIPT A <br />BY: <br />FORM B (6-29-88) THIS FORM MUST K ACOMANU FACIlTT/WR AFRWATWK r V lSgl -A , URLM A V "Mw NAi neem PILtu <br />1 DATA. PAU,:ESSING COPY 2 LOCAL AGENCY C094 j FILE COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.