My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
4 (STATE ROUTE 4)
>
14201
>
2800 - Aboveground Petroleum Storage Program
>
PR0516683
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:08:20 AM
Creation date
10/11/2018 2:46:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516683
PE
2831
FACILITY_ID
FA0001516
FACILITY_NAME
UNION POINT MARINA BAR & GRILL INC
STREET_NUMBER
14201
Direction
W
STREET_NAME
STATE ROUTE 4
City
STOCKTON
Zip
95206
APN
13113005
CURRENT_STATUS
01
SITE_LOCATION
14201 W HWY 4
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BULK STORAGE CONTAINERS: § 112.7(i), §112.8(c) and/or§112.12(c) <br /> ❑ Failure to conduct evaluation of field-constructed aboveground containers for risk of discharge or <br /> failure due to brittle fracture or other catastrophe- 112.7(i).........................................................................300.00 <br /> ❑ Material and construction of containers not compatible with the oil stored and the conditions of storage <br /> such as pressure and temperature- 112.8(c)(1).........................................................................450.00 <br /> ❑ Secondary containment capacity is inadequate- 112.8(c)(2).........................................................750.00 <br /> ❑ Secondary containment systems are not sufficiently impervious to contain oil- 112.8(c)(2).................. 375-00 <br /> ❑ Completely buried metallic tanks are not protected from corrosion or are not subjected to. <br /> regular pressure testing- 112.8(c)(4).................................................................................... 150.00 <br /> ❑ Buried sections of partially buried metallic tanks are not protected from corrosion- 112.8(c)(5)............. 150.00 <br /> ❑ Above ground containers are not subject to periodic integrity testing techniques such as <br /> visual inspections,hydrostatic testing, or other nondestructive testing methods - 112.8(c)(6)..................450.00 <br /> ❑ Above ground tanks are not subject to visual inspections- 112.8(c)(6)............................................. 450.00 <br /> ❑ Records of inspections (or customary business records) do not include inspections of container <br /> supports/foundation, signs of container deterioration, discharges and/or accumulations of oil <br /> inside diked areas - 112.8(c)(6).................. ......................................................................... 75.00 <br /> ❑ Stearn return/exhaust of internal heating coils that discharge into an open water course are <br /> not monitored, passed through a settling tank, skimmer, or other separation system- l 12.8(c)(7)............. 150.00 <br /> ❑ Container installations are not engineered or updated in accordance with good engineering practice <br /> because none of the following are present- 112.8(c)(8).............................................................................450.00 <br /> -high liquid level alarm with audible or visual signal, or audible air vent- 112.8(c)(8)(i) <br /> -high liquid level pump cutoff devices set to stop flow at a predetermined level - 112.8(c)(8)(ii) <br /> -direct audible or code signal communication between container gauger and pumping station- 112.8(c)(8)(iii) <br /> -fast response system for determining liquid level of each bulk storage container, or direct vision gauges <br /> with a person present to monitor gauges and the overall filling of bulk storage containers - 112.8(c)(8)(h,) <br /> ❑ No testing of liquid Ievel sensing devices to ensure proper operation- 112.8(c)(8)(0............................ 75.00 <br /> ❑ Effluent treatment facilities not observed frequently to detect possible system upsets that could cause a <br /> discharge as described in §112,I(b) - 112.8(c)(9).....................................................................150.00 <br /> ❑ Causes of leaks resulting in accumulations of oil in diked areas are not promptly corrected- 112.8(c)(10)..450.00 <br /> ❑ Mobile or portable storage containers are not positioned or located to prevent discharged oil from <br /> reaching navigable water, or have inadequate secondary containment- 112.8(c)(11)...........................150.00 <br /> ❑ Secondary containment inadequate for mobile or portable storage tanks - 112.8(c)(11)........................500.00 <br /> ❑ Plan has inadequate or no discussion of bulk storage tanks...........................................................75.00 <br /> Page 5 of 6 <br />