Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.slgov.org/ehd/unitiii.html <br /> CONTINUATION FORM Page: 4 of 4 <br /> OFFICIAL INSPECTION REPORT Date: 06/20/11 <br /> Facility Address: 4704 Fite Ct., Stockton Program: APSA <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> 10. (continued) the Plan, either at the beginning or end of the Plan, or in a log or appendix to the Plan. <br /> As a result of this review and evaluation, the SPCC Plan must be amended within 6 months of review, <br /> and recertified by a professional engineer if any technical amendments were made. Immediately <br /> conduct a review of the facility SPCC Plan and make any necessary amendments. <br /> 18. A facility diagram was not included with the Plan. The Plan shall include a facility diagram which <br /> must mark the location and contents of each fixed storage container and the storage area where mobile <br /> or portable containers are located. It must also include all transfer stations and connecting pipes, <br /> including intra-facility gathering lines. Immediately provide a facility diagram which includes all of the <br /> required information. Submit a legible copy of the facility diagram to the EHD by July 20, 2011. <br /> 24. The contact information for the San Joaquin County Office of Emergency Services (SJC OES) was <br /> not included in the SPCC Plan. The SPCC Plan must include a contact list and phone numbers for the <br /> facility response coordinator, National Response Center, cleanup contractors with whom you have an <br /> agreement for response, and all appropriate federal, state, and local agencies who must be contacted in <br /> case of a discharge. Immediately update the contact list to include the most current version of the <br /> required information. <br /> 48. Integrity testing has not been conducted on the motor oil and diesel tanks. The facility shall test or <br /> inspect each aboveground container for integrity on a regular schedule and whenever you make material <br /> repairs. Examples of these integrity tests include, but are not limited to: visual inspection, hydrostatic <br /> testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems of non- <br /> destructive testing. Comparison records and other records of inspections and tests must be maintained <br /> on site with the SPCC Plan. Immediately conduct all necessary integrity testing and maintain records on <br /> site as required. <br /> 50. Liquid level sensing devices have not been tested. Liquid level sensing devices must be installed in <br /> accordance with 40 CFR 112.8 and shall be regularly tested to ensure proper operation. Immediately <br /> conduct all necessary testing of liquid level sensing devices. <br /> Complete and submit a copy of the Return to Compliance Certification to the EHD by July 20, 2011 <br /> along with a statement documenting the corrective actions that have been or will be taken for each <br /> violation and any supporting paperwork. <br /> Provided: Return to Compliance Certification form <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACILI SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> EHD Inspector: Y' Title: <br /> EHD 2&02-0R /10/10 CONTINUATION FORM <br />