Laserfiche WebLink
SAN JOAQU I N <br />COUhliY <br />Environmental Health Department <br />FA0006141 PRO524264 SC333 08/21/2018 <br />EHD 28-01 Rev. 11/07/2017 Page 2 of 4 Aboveground Petroleum Storage Act OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />A L POWELL TRUCKING <br />Facility Address: <br />23534 E ARTHUR RD, ESCALON <br />Date: <br />August 21, 2018 <br />Qualified Facility - Tier II <br />502 CFR 112.6(b)(2) Tier II Qualified Facility Plan technical amendment not certified by the owner or a PE V R COS <br />503 CFR 112.6(b)(3), <br />112.6(b)(4) <br />Failure to have a PE certify in writing alternative measures for a Tier II Qualified Facility V R COS <br />504 CFR 112.6(b)(4)(i) Failure of owner to assure that a PE makes all required attestations in a Tier II Plan V R COS <br />General Requirements for SPCC Plans <br />601 CFR 112.7 Failure of Plan to fulfill basic requirements including a cross-referencing section V R COS <br />602 CFR 112.7(a)(2) Plan failed to discuss equivalent environmental protection, if applicable V R COS <br />603 CFR 112.7(a)(3) Failed to adequately describe the physical layout of the facility in the Plan V R COS <br />604 CFR 112.7(a)(3)(i) Plan failed to include oil type and storage capacity for each container V R COS <br />605 CFR 112.7(a)(3)(ii) Plan failed to adequately discuss discharge prevention measures, including routine handling V R COS <br />606 CFR 112.7(a)(3)(iii) Plan failed to adequately discuss facility drainage or drainage controls V R COS <br />607 CFR 112.7(a)(3)(iv) Plan failed to include countermeasures for discharge discovery, response and cleanup V R COS <br />608 CFR 112.7(a)(3)(v) Plan failed to address disposal methods for recovered materials V R COS <br />609 CFR 112.7(a)(3vi), <br />112.7(a4) <br />Plan failed to adequately contain procedures for reporting a discharge V R COS <br />610 CFR 112.7(a)(5) Discharge procedures are not adequately addressed if the facility has no response plan V R COS <br />611 CFR 112.7(b) Plan failed to include a description of potential equipment failure or provide equivalence V R COS <br />612 CFR 112.7(c) Plan failed to include secondary containment, diversionary structures, or equip to prevent discharge V R COS <br />613 CFR 112.7(c) Failure to provide appropriate secondary containment, diversionary structures or equipment V R COS <br />614 CFR 112.7(d) PE certified Plan failed to explain impracticability of containment/diversionary structures V R COS <br />615 CFR 112.7(d) Failure to perform integrity and leak testing when claiming secondary containment impracticability V R COS <br />616 CFR 112.7(d)(1) Failure to prepare an oil spill contingency plan when claiming impracticability of structures V R COS <br />617 CFR 112.7(d)(2) No written commitment of manpower, equipment, and materials to control and remove oil discharge V R COS <br />618 CFR 112.7(e), 112.8(c) <br />6) <br />Failed to keep records of procedures, inspections, or integrity tests for three years V R COS <br />619 CFR 112.7(f)(1) Failed to train personnel on all discharge prevention details listed in this section V R COS <br />620 CFR 112.7(f)(2) Failed to designate a person accountable for discharge prevention V R COS <br />621 CFR 112.7(f)(1) Failure to include in the SPCC Plan an adequate description of employee training V R COS <br />622 CFR 112.7(f)(3) Failure to conduct complete annual discharge prevention briefings for oil -handling personnel V R COS <br />623 CFR 112.7(g) Plan failed to address security of site and valves, lock out/tag out, and lighting V R COS <br />624 CFR 112.7(g) Facility failed to implement security of site and valves, lock out/tag out, and lighting V R COS <br />625 CFR 112.7(h) Plan failed to adequately discuss facility tank car and tank truck loading/unloading rack V R COS <br />626 CFR 112.7(h)(1) Loading/unloading rack containment system not adequate to contain spill V R COS <br />627 CFR 112.7(h)(2) Failed to provide vehicular departure system for loading and unloading racks V R COS <br />628 CFR 112.7(a)(1), <br />112.70) <br />Failure to include in the Plan discussion of conformance with Federal and State requirements V R COS <br />629 CFR 112.7(i) Failed to evaluate field constructed container for brittle fracture and take appropriate action V R COS <br />FA0006141 PRO524264 SC333 08/21/2018 <br />EHD 28-01 Rev. 11/07/2017 Page 2 of 4 Aboveground Petroleum Storage Act OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com