Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.segov.org/ehd <br /> CONTINUATION FORM Page: 4 of 4 <br /> OFFICIAL INSPECTION REPORT Date: 08/27/13 <br /> Facility Address: Gordon Trucking Inc 12550 South Harlan Road, Lathrop Program: APSA <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> 504. Failed to show diagram of location and contents of petroleum containers for the new, used, gear oil <br /> tanks. The plan shall include a facility diagram which must mark the location and contents of each fixed <br /> storage container and the storage area where mobile or portable containers are located. It shall include <br /> all transfer stations and connecting pipes, including intra-facility gathering lines. Update facility diagram <br /> to include all required information. Submit a legible copy of the updated facility diagram to EHD. <br /> 510. Failed to include correct phone numbers for the clean up contractors and phone number for SJC <br /> EHD on the contact list. Draft SPCC Plan list Safety Kleen as the hazardous waste hauler contractors. <br /> Facility has a contract with a new hazardous waste hauler for waste removal. SJC EHD phone number <br /> should be listed as a local CUPA agency in the SPCC Plan. SPCC Plan must include contact list and <br /> phone numbers for the facility response coordinator, National Response Center, clean up contractors <br /> with whom you have an agreement for response, and all appropriate federal, state, and local agencies <br /> who must be contacted in case of discharge. Immediately update the contact list to include the most <br /> current version of the required information. Submit an explanation how this will be in the finalized Plan. <br /> Submit to SJC EHD within 30 days (09/27/13): <br /> 1. one copy of the completed "Return to Compliance Certification" form <br /> 2. a written corrective action statement for each of the above violations <br /> (do not submit finalized SPCC to EHD - have readily available for review during next inspection) <br /> Notes: <br /> -Draft states that inspection on AST must be done. Unclear the frequency (monthly, weekly, annually) of <br /> when inspections must be completed. CFR112.7(e) <br /> -Draft states an "emergency coordinator" for spills but in SPCC, it must state "discharge prevention <br /> coordinator". CFR112.7(f (2) <br /> -No sure where the information is on security & addresses the appropriateness of security lighting. CFR <br /> 112.7(g) <br /> -If facility has an aboveground emergency generator tank, contents must be in the plan. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> EHD!:�or- Received By: Title: <br /> EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />