3003
>
2800 - Aboveground Petroleum Storage Program
>
PR0516435
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 3:50:03 PM
Creation date
10/16/2018 9:54:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516435
PE
2834
FACILITY_ID
FA0007088
FACILITY_NAME
TESORO STOCKTON TERMINAL
STREET_NUMBER
3003
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
145-030-10
CURRENT_STATUS
01
SITE_LOCATION
3003 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sjgov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TESORO STOCKTON TERMINAL 3003 NAVY DR, STOCKTON November 04, 2015 <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 723 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping n V ❑R ❑COS <br /> 724 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ■V ❑R o COS <br /> 726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves, piping,and appurtenances ❑V ❑R ❑COS <br /> 727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 728 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V ❑R ❑COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> Overall Inspection Comments: <br /> A checklist of findings was left onsite at the time of inspection, the full report will be provided at a later date. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of report. <br /> Please be aware as of January 1, 2013, all businesses are required to submit all new (or any changes to existing) <br /> Aboveground Petroleum Storage Act (APSA) information online to the California Environmental Reporting System <br /> (CERS) at http://cers.calepa.ca.gov in addition to any other relevant activities and required fields. No later than <br /> January 1, 2014, all APSA data must be entered and or updated in CERS. <br /> Provided: Return to Compliance Certification form, Schedule of free CUPA classes <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS WILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHUS CURRENT HOURLY RATE. <br /> Received B Q Received By(printed name and title): Date: <br /> (signature): (�'�/ John Walker, Manager, Terminals, Northwest I I _ L—( t <br /> Inspector Inspector(printed name and title): Inspector Phone: <br /> (signatu - __. STACY RIVERA, Senior REHS (209) 468-3440 <br /> Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.