My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
11396
>
2800 - Aboveground Petroleum Storage Program
>
PR0528240
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:26 PM
Creation date
10/16/2018 11:20:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528240
PE
2832
FACILITY_ID
FA0003786
FACILITY_NAME
T&T TRUCKING INC
STREET_NUMBER
11396
Direction
N
STREET_NAME
STATE ROUTE 99
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05926010
CURRENT_STATUS
01
SITE_LOCATION
11396 N HWY 99 E FRONTAGE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> T&T TRUCKING INC 1 11396 N HWY 99 E FRONTAGE RD, LODI December 04, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 711 CFR 112.8(c)(6)Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> The 20,000 gallon, 12,00 gallon and 10,000 gallon tanks were not tested on schedule by a certified SP-001 <br /> inspector.The SPCC plan calls for formal inspections by a certified SP-001 inspector every 20 years.The age of the <br /> tanks could not be determined at the time of the inspection. Each aboveground container shall be tested and <br /> inspected for integrity on a regular schedule and whenever repairs are made. The qualifications of personnel <br /> performing tests and inspections,frequency and type of testing and inspections that take into account container <br /> size, configuration, and design shall be determined in accordance with industry standards. Examples of these <br /> integrity tests include, but are not limited to:visual inspection, hydrostatic testing, radiographic testing, ultrasonic <br /> testing, acoustic emissions testing, or other systems of non-destructive testing. Comparison records and other <br /> records of inspections and tests must be maintained on site. Immediately provide evidence that the tanks are not <br /> yet due for formal inspections or conduct the necessary testing and submit a copy of the test results to the EHD or <br /> provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork by January 3, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: December 04, 2018 Inspector: Inspector Phone: <br /> Printed Name and Title: CESAR RUVALCABA, REHS (209)953-6213 <br /> Grant Galli, Director of Operations <br /> FA0003786 PR0528240 SCO01 12/04/2018 <br /> EHD 28-01 Rev.09/27/2018 Page 5 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.