My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
19400
>
2800 - Aboveground Petroleum Storage Program
>
PR0536577
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:26 PM
Creation date
10/16/2018 11:50:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0536577
PE
2832
FACILITY_ID
FA0003748
FACILITY_NAME
J S G TRUCKING COMPANY
STREET_NUMBER
19400
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
01322033
CURRENT_STATUS
01
SITE_LOCATION
19400 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sugov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> J S G TRUCKING COMPANY 19400 N HWY 99 , ACAMPO March 30, 2015 <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 723 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping ❑V ❑R ❑COS <br /> 724 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ❑V ❑R ❑COS <br /> 727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 728 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V ❑R ❑COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 301 CFR 112.5(a) Failed to amend Plan as necessary. <br /> The 3-19-15 Spill Prevention, Control, and Countermeasure (SPCC) Plan lists a 270 gallon good oil tank and a 170 <br /> gallon used oil tank. These tanks are actually 110 gallons each. The SPCC Plan must be amended when there is a <br /> change in the facility design, construction, operation, or maintenance that materially affects its potential for a <br /> discharge, within 6 months of the change, and implemented as soon as possible, not later than 6 months following <br /> preparation of the amendment. Immediately make all necessary amendments to the SPCC Plan to accurately <br /> represent the procedures and policies currently in place at the facility. This was corrected on site. <br /> This is a minor violation. <br /> 602 CFR 112.7 Plan lacks approval of management to fully commit the necessary resources to implement the Plan. <br /> The 3-19-15 Spill Prevention, Control, and Countermeasure (SPCC) Plan has not yet been signed by a member of JSG <br /> Trucking Company's management. The SPCC Plan must have the full approval of management at a level of authority to <br /> commit the necessary resources to fully implement the Plan. Immediately obtain required management approval for <br /> the SPCC Plan for this facility. This was corrected on site. <br /> This is a Class II violation. <br /> Receive ' Inspector: Phone: Date: <br /> (initial): ARIS VELOSO, Senior REHS (209) 468-3453 03/30/2015 <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.