Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.orq/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Fac Uty Name- Facility Address: Date: <br /> MOUNTAIN VALLEY EXPRESS u4�- 1 1ANTECA c)vember 20, 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> CFR 112.8(c)(8)(-iv) Failed to provide each container with a high level monitoring device. <br /> According to the onsite SPCC plan (page 29, s :n 8.28) "site personnel are present throughout filling operations". <br /> Per Mr. Souza, facility personnel doesn't monitor fuel delivery operations . At least one of the following devices must <br /> be installed in each container: <br /> - High liquid level alarm with audible or visual signal <br /> - High liquid level pump cutoff device set to stop flow at a predetermined content level <br /> - Direct audible or code signal communication between the container gauger and the pumping station <br /> - Fast response system, such as digital computer, telepulse, or direct vision gauge. If a direct vision gauge is <br /> being used for determining the liquid level of each tank, a person must be present to monitor gauges and the overall <br /> filling of the tanks. <br /> Ensure that an approved liquid level sensing device is utilized in accordance with CFR 112.8 and implement necessary, <br /> procedures to ensure that the devices are fully functional and in use at all times during tank filling operations, or <br /> provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance CertificGL r rel co the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 12-20-2015. <br /> Please be aware as of January 1, 2013, all businesses are required to submit all new (or any changes to existing) <br /> Aboveground Petroleum Storage Act (APSA) information online to the California Environmental Reporting System <br /> (CERS) at http://cers.calepa.ca.gov in addition to any other relevant activities and required fields. No )ater than <br /> January 1, 2014.. all APSA data must be entered and or updated in CERS. <br /> NOTES: <br /> The reviewed SPCC pian was dated February 2011. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED ATTHE CURRENT HOURLY RATE <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received By Received By(printed name and title): Date: <br /> (signature ? �—�� inuuca, `✓i- s`luu iu. <br /> Inspector Inspector(printed name and title): Inspdctor P one: <br /> (signature): ELENA MANZO, Senior Rt_ 209 3-7( <br /> Page 6 of 5 <br />