Laserfiche WebLink
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FORWARD INC LANDFILL 9999 S AUSTIN RD, MANTECA December 26, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 711 CFR 112.8(c)(6)Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> The 10,000 gallon diesel,was not tested on schedule by qualified personnel.The SPCC plan calls for STI SP-001 <br /> industry standard integrity testing on the 10,000 gallon diesel tank every 20 years. Per facility personnel,the tank <br /> may be over 20 years in service. Each aboveground container shall be tested and inspected for integrity on a <br /> regular schedule and whenever repairs are made. The qualifications of personnel performing tests and inspections, <br /> frequency and type of testing and inspections that take into account container size, configuration, and design shall <br /> be determined in accordance with industry standards. Examples of these integrity tests include, but are not limited <br /> to:visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other <br /> systems of non-destructive testing. Comparison records and other records of inspections and tests must be <br /> maintained on site. Immediately conduct the necessary testing and submit a copy of the test results to the EHD, or <br /> provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 712 CFR 112.8(c)(6)Failed to test or inspect each container for integrity based on industry standards. <br /> The SPCC plan references industry standard STI SP-001 but deviates from the annual inspections by the facility. <br /> The plan does not mention annual inspections, as called for in the standard. Each aboveground container shall be <br /> tested and inspected for integrity on a regular schedule and whenever repairs are made. The qualifications of <br /> personnel performing tests and inspections,frequency and type of testing and inspections that take into account <br /> container size, configuration, and design shall be determined in accordance with industry standards. Examples of <br /> these integrity tests include, but are not limited to:visual inspection, hydrostatic testing, radiographic testing, <br /> ultrasonic testing, acoustic emissions testing, or other systems of non-destructive testing. Comparison records and <br /> other records of inspections and tests must be maintained on site. Immediately amend the plan to comply with <br /> referenced industry standards, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by January 25, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: December 26, 2018 Inspector: Inspector Phone: <br /> Printed Name and Title: CESAR RUVALCABA, REHS (209)953-6213 <br /> //t4/RubLamirez, Landfill Operations Manager <br /> FA0007101 PR0515721 SCO01 12/26/2018 <br /> EHD 28-01 Rev.09/27/2018 Page 5 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />