My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLUFF
>
500
>
2800 - Aboveground Petroleum Storage Program
>
PR0516579
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2018 1:18:44 AM
Creation date
10/18/2018 11:46:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0516579
PE
2832
FACILITY_ID
FA0009875
FACILITY_NAME
FORD CONST CO INC
STREET_NUMBER
500
Direction
N
STREET_NAME
CLUFF
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
04934013
CURRENT_STATUS
01
SITE_LOCATION
500 N CLUFF AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd/unitiii.html <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility Ford Construction Com an Inc Facility 500 N. Cluff Ave. Lodi, CA 95240 Inspection Mar 23, 2012 <br /> Name: P y Address: Date: <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1 =Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> SPCC Plan Requirements for Onshore Facilities(excluding production facilities)(continued) <br /> 605 CFR 112.8(b)(5) Failed to provide two"lift"pumps, one permanently installed,where drainage waters are continuously <br /> treated in more than one treatment unit, or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 606 CFR 112.8(c)(1) Container not compatible with oil stored and/or storage conditions, or failed to provide equivalence as <br /> allowed by CFR 112.7 a 2 <br /> Failed to provide sufficient secondary containment capacity for a bulk storage tank that would hold the <br /> 607 CFR 112.8(c)(2) volume of the largest container plus sufficient freeboard to contain precipitation and/or diked area is not <br /> sufficiently impervious to contain discharged oil <br /> Allowed drainage of uncontaminated rainwater from a diked area and failed to: (i)keep bypass valves <br /> 608 CFR 112.8(c)(3) sealed closed; (ii)inspect retained rainwater prior to discharge; (iii)open bypass valve and reseal it <br /> under responsible supervision; (iv)maintain adequate records of such events, or provide equivalence <br /> as allowed by CFR 112.7(a)(2) <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were <br /> 609 X CFR 112.8(c)(6) made; inspect containers and container supports; or keep records of inspections and tests, or provide <br /> equivalence as allowed by CFR 11 2.7 a 2 <br /> 610 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils, or provide <br /> equivalence as allowed by CFR 11 2.7 a 2 <br /> 611 CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices, or provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> 612 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause <br /> a discharge, or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 613 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas, or <br /> provide equivalence as allowed by CFR 11 2.7 a 2 <br /> Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> 614 CFR 112.8(c)(11) capacity that will hold the volume of the largest container plus sufficient freeboard to contain <br /> precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 615 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed, or provide equivalence as allowed by CFR <br /> 112.7 a 2 <br /> Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not <br /> 616 CFR 112.8(d)(2) in service or in standby service for an extended time, or provide equivalence as allowed by CFR <br /> 112.7 a 2 <br /> 617 1 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction, or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 618 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves, piping, and appurtenances, or provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> 619 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation, modification, <br /> construction, relocation, or replacement, or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 620 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and <br /> other oil transfer operations, or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> Other Violations <br /> 999 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE <br /> Inspector. _ Received By: Title. <br /> EHD 28-02 Rev 03/09/12 Page 3 APSA INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.