Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />CHEROKEE FREIGHT LINES <br />Facility Address: <br />5463 E CHEROKEE RD, STOCKTON <br />TDate: <br />anuary 13, 2017 <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />703 <br />CFR 112.8(b)(3), <br />112.8(b)(4) <br />Failed to design facility drainage system from undiked areas to retain in the facility <br />❑ V ❑ R ❑ COS <br />❑ V ❑ R ❑ COS <br />704 <br />CFR 112.8(b)(5) <br />Failed to provide two lift pumps for more than one continuous treatment unit <br />Container not compatible with oil stored and/or storage conditions <br />705 <br />CFR 112.8(c)(1) <br />❑ V ❑ R ❑ COS <br />706 <br />CFR 112.8(c)(2) <br />Failed to provide and maintain adequate secondary containment <br />■ V ❑ R ❑ COS <br />707 <br />CFR 112.8(c)(3) <br />Failure to follow the criteria of this section while allowing drainage of uncontaminated rainwater <br />❑ V ❑ R ❑ COS <br />708 <br />CFR 112.8(c)(3)(iv) <br />Failed to maintain records of drainage from diked areas <br />❑ V ❑ R ❑ COS <br />709 <br />CFR 112.8(c)(5) <br />Failed to provide corrosion protection for partially buried tanks <br />❑ V ❑ R ❑ COS <br />710 <br />CFR 112.8(c)(6) <br />Plan failed to adequately discuss procedures to test or inspect each container for integrity <br />❑ V ❑ R ❑ COS <br />711 <br />CFR 112.8(c)(6) <br />Failed to perform scheduled tank tests or inspections by appropriately qualified personnel <br />■ V ❑ R ❑ COS <br />712 <br />CFR 112.8(c)(6) <br />Failed to test or inspect each container for integrity based on industry standards <br />❑ V ❑ R ❑ COS <br />713 <br />CFR 112.8(c)(7) <br />Failed to provide effective leakage control from defective internal heating coils <br />❑ V ❑ R o COS <br />714 <br />CFR 112.8(c)(8)(kiv) <br />Failed to provide each container with a high level monitoring device <br />■ V ❑ R ❑ COS <br />715 <br />CFR 112.8(c)(8)(v) <br />Failed to regularly test liquid level sensing devices to ensure proper operation <br />■ V ❑ R ❑ COS <br />716 <br />CFR 112.8(c)(9) <br />Failed to observe effluent treatment frequently enough to detect potential discharge <br />❑ V ❑ R ❑ COS <br />717 <br />CFR 112.8(c)(10) <br />Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas <br />❑ V ❑ R ❑ COS <br />718 <br />CFR 112.8(c)(11) <br />Failed to provide sufficient secondary containment capacity for mobile or portable containers <br />■ V ❑ R ❑ COS <br />719 <br />CFR 112.8(c)(11) <br />Failed to locate mobile or portable containers to prevent discharge <br />❑ V ❑ R ❑ COS <br />720 <br />CFR 112.8(d)(1) <br />Failed to take corrective action on buried piping when exposed for any reason <br />❑ V ❑ R ❑ COS <br />721 <br />CFR 112.8(d)(1) <br />Failed to provide corrosion protection for buried piping <br />❑ V ❑ R ❑ COS <br />722 <br />CFR 112.8(d)(2) <br />Failed to cap/blank-flange connection at transfer point and mark its origin if not in service <br />❑ V ❑ R ❑ COS <br />723 <br />CFR 112.8(d)(3) <br />Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction <br />❑ V ❑ R ❑ COS <br />724 <br />CFR 112.8(d)(4) <br />Failed to regularly inspect aboveground valves, piping, and appurtenances <br />■ V ❑ R ❑ COS <br />725 <br />CFR 112.8(d)(4) <br />Failed to conduct integrity and leak testing on buried piping any time it is worked on <br />❑ V ❑ R ❑ COS <br />726 <br />CFR 112.8(d)(5) <br />Failed to adequately warn vehicles entering facility to protect piping and other transfer operations <br />❑ V ❑ R ❑ COS <br />Other Violations <br />4010 See below Unlisted Administration/Documentation violation <br />4020 See below Unlisted Training violation <br />4030 See below Unlisted Operations/Maintenance violation <br />■ V ❑ R ❑ COS <br />❑ V ❑ R ❑ COS <br />❑ V ❑ R ❑ COS <br />4040 <br />See below <br />Unlisted Release/Leaks/Spills violation <br />c V ri R - COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # Remarks <br />Page 3 of 4 <br />