Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility MR TRUCKER INC Facility 2710 LOOMIS RD Inspection Aug 31, 2010 <br /> Name Address: Date <br /> VIOLATIONS <br /> # V RCode Section HSC=CA Health and SafetyCode:CFR=Code of Federal Regulations;V=Violation,RV=Repeat violation <br /> Specific requirements of HSC 25270 4 5(a)are identified as CFR code sections beginning with 112 <br /> Failed to: test each aboveground container for integrity on a regular schedule or when repairs were made; <br /> 48 CFR 112.8(c)(6) inspect containers and container supports:or keep records of inspections and tests, or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 49 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils, or provide equivalence <br /> as allowed by CFR 11 2.7(a)(2) <br /> 50 CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices, or provide equivalence as allowed <br /> by CFR 11 2.7(a)(2) <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> discharge, or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 52 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas.or provide <br /> equivalence as allowed by CFR 11 2.7 a 2) <br /> 53 CFR 112.8(c)(11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> capacity that will hold the volume of the largest container plus sufficient freeboard to contain precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed, or provide equivalence as allowed by CFR <br /> 112.7 a) 2 <br /> 55 CFR 112.8(d)(2) Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not in <br /> service or in standby service for an extended time, or provide equivalence as allowed by CFR 112,7(a)(2) <br /> 56 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction,or provide equivalence as allowed by CFR 11 2.7 a 2 <br /> 57 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves, piping, and appurtenances,or provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> 58 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation, modification,construction. <br /> relocation.or replacement, or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 59 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and other <br /> oil transfer operations.or provide equivalence as allowed by CFR 11 2.7 a 2) <br /> 999 Other See attached"Continuation-Official Inspection Report"for violation(s) not listed above. <br /> Routine Aboveground Petroleum Storage Act Program Inspection <br /> SPCC is located on site. <br /> Note: If the 12,000 gallon diesel aboveground storage tank will no longer be used then it must be <br /> permanently closed per CFR, section 112.2. Permanently closed means all liquid and sludge has been <br /> removed from the tank and lines, all connecting lines and piping have been disconnected and blanked off, <br /> all valves except vent have been closed and locked and a conspicuous sign has been posted on the tank <br /> stating that it is "permanently closed" and noting the date of closure. Provide documentation of the tank <br /> closure if applicable. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY <br /> RATE.THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Ins clot Phone Title <br /> (209)468-9848 <br /> EHD 28-02 Rev 2/19/10 Page 3 APSA INSPECTION REPORT <br />