My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:27:51 PM
Creation date
10/19/2018 10:08:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
663
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 10 A Q U l N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> LOVE'S COUNTRY STORES OF CALIF#223 1 1553 COLONY RD, RIPON August 09, 2018 <br /> UST System observations <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty c V Li R c COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements c V c R c COS <br /> 321 CCR 2635(b)(2) Overrill prevention was overridden c V o R c COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status c V c R c COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system fated to meet exemption status c V c R c COS <br /> 324 CCR 2717.1(g) Tampered with red tag c V c R c COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST c V c R c COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms n V ❑R n COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored u V c R c COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements c V c R c COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements c V c R c COS <br /> 330 CCR 2636(0(5) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system c V u R c COS <br /> 331 CCR 2630(d) Secondarily contained piping not maintained to allow liquid to drain into sump c V o R c COS <br /> 332 CCR 2631(b),2631(d) Pnmary and/or secondary containment not constructed in accordance with the established standards c V c R c COS <br /> SingleaMalled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V c R c COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed n V c R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph fine test for conventional suction piping not performed(pre-January 1964) c V c R c COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) n V c R c COS <br /> other Violations <br /> 2010 See below Unlisted General violation c V n R c COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item Remarks <br /> 111 CCR 2638(a)Failed to test monitoring and leak detection equipment annually. <br /> The 87-91 split tank annular sensor was observed with splicing outside of the junction box.All monitoring <br /> equipment shall be installed, calibrated. operated and maintained in accordance with manufacturer's instructions. <br /> Immediately repair the 87-91 split tank annular sensor, and properly install according to manufacturer's <br /> recommendations, and obtain a repair permit if necessary. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork within 30 days of receipt of this report. <br /> FA0012659 PRO516526 Scoot 08/09/2018 <br /> EHD 23-01 Rev.101312017 Page 3 of 4 underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue Stockton, California 95205 1 T 209 468-3420 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.