My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:27:51 PM
Creation date
10/19/2018 10:08:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
663
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />16. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard )EUARONMWAL HE <br />❑ Other (Spec) DEPARTMENT <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .002 <br />Sump # 5 Sump # 6 <br />Sump # 7 Sump # 8 <br />Sump Diameter: 42" 42" <br />42" 42" <br />Sump Depth: <br />75" <br />74''/2" <br />74 %" <br />74" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />No Piping <br />No Piping <br />No Piping <br />No Piping <br />Highest Piping Penetration: <br />Penetrations <br />Penetrations <br />Penetrations <br />Penetrations <br />Height from Tank Top to Lowest <br />42" <br />42" <br />42" <br />30" <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of Sump Tested' <br />Water Line 44" <br />Water Line 44" <br />Water Line 44" <br />Water Line 44" <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />No <br />No <br />No <br />No <br />product and water)?' <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail-safe <br />No <br />No <br />No <br />No <br />shutdown?* <br />Was fail-safe verified to be <br />N/A <br />N/A <br />N/A <br />N/A <br />operational?* <br />Wait time between applying water <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />and starting test: <br />Test Start Time: <br />11:30 <br />11:35 <br />11:40 <br />11:45 <br />Initial Reading (RI): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test End Time: <br />12:00 <br />12:05 <br />12:10 <br />12:15 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF-Ri): <br />0 <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />Pass <br />Pass <br />Pass <br />Pass <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced and <br />Yes <br />Yes <br />Yes <br />Yes <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Piping Sump #5 is for Annular Riser and Tank Probe Riser for Tank #1 Diesel. <br />Piping Sump #6 is for Annular Riser and Tank Probe Riser for Tank #2 Diesel. <br />Piping Sump #7 is for Annular Riser and Tank Probe Riser for Tank #3 Regular. <br />Piping Sump #8 is for Annular Riser and Tank Probe Riser for Tank #4 Regular. <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to � of the questions indicated with an <br />asterisk(*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />LTH <br />
The URL can be used to link to this page
Your browser does not support the video tag.