Laserfiche WebLink
6/24/09 <br />Leak Detection Equipment Functional Compatibility Claims and Validation <br />Type Equipment <br />Equipment Name <br />Functional Com ati <br />ity Claim <br />Validation Method <br />Comments <br />Ethanol % <br />Biodiesel <br />(U.L. Listed, Independent Testing, <br />(%) <br />Internal Testing, Engineering Analysis, <br />W/Water <br />W/Out <br />Detection <br />Water <br />Unsubstantiated Manufacturer Claim) <br />Detection <br />Interstitial Detector <br />- 847990-001 (Disp. <br />N/A <br />EQXX — Control <br />(Liquid -phase) <br />Pan Sensor) <br />15%' <br />20%2 <br />1) UL Listed in File No. MH 11766 <br />Monitoring & <br />- 847990-002 <br />2) Engineering Analysis <br />Auxiliary <br />(Differentiating Disp. <br />Equipment <br />Pan Sensor <br />Interstitial Detector <br />- 794380-301 (Single <br />N/A <br />EQXX — Control <br />(Liquid -phase) <br />Stage Hydrostatic <br />15%' <br />20%2 <br />1) UL Listed in File No. MHI 1766 <br />Monitoring & <br />Sensor) <br />2) Engineering Analysis <br />Auxiliary <br />- 794380-302, 303 <br />Equipment <br />(Dual Stage Hydrostatic <br />Sensor <br />Interstitial Detector <br />- 794380-208 and <br />N/A <br />EQXX — Control <br />(Liquid -phase) <br />794380-209 (Piping <br />15%' <br />20%2 <br />1) UL Listed in File No. MH 11766 <br />Monitoring & <br />Sump Sensor) <br />2) Engineering Analysis <br />Auxiliary <br />- 794380-340 (Micro- <br />Equipment <br />Sensor <br />Interstitial Detector <br />- 794380-343 (Discrim. <br />N/A <br />EQXX — Control <br />(Liquid -phase) <br />Int. Sensor) <br />15%' <br />20%' <br />1) UL Listed in File No. MH 11766 <br />Monitoring & <br />2) Engineering Analysis <br />Auxiliary <br />Equipment <br />Interstitial Detector <br />- 794380-344 (Micro- <br />N/A <br />EQXX — Control <br />(Liquid -phase) <br />Sensor) <br />85%' <br />20%2 <br />1) UL Listed in File No. MH 11766 <br />Monitoring & <br />2) Engineering Analysis <br />Auxiliary <br />Equipment <br />Interstitial Detector <br />- 794380-323 (Position <br />N/A <br />EQXX — Control <br />(Liquid -phase) <br />Sensitive Sensor) <br />85%' <br />20%2 <br />1) UL Listed in File No. MHI 1766 <br />Monitoring & <br />2) Engineering Analysis <br />Auxiliary <br />Equipment <br />4 of 5 <br />Note: NWGLDE's Disclaimer posted on its Website includes the statement: "Unless specifically indicated on the indivdhqi� dat*,sheetW[re equipment listed by <br />the NWGLDE has not been evaluated using alternative fuels." However, evaluation with alternative fuel is for leak deoAtibh pcgrm e -only — not <br />compatibility of material with alternative fuels. <br />