RECEIVE <br />19. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />-.7 <br />Test Method Developed By: <br />Li Sump Manufacturer <br />Li Other (Spec) <br />Industry Standard Pro <br />�EA:TN DEAftTMENT <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Specie) <br />Vacuum <br />X Hydrostatic <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: <br />.002 <br />Fill Sump # I <br />Fill Sump # 2 <br />Fill Sump # 3 <br />Fill Sump # 44111 <br />Sump Diameter: <br />42" <br />42" <br />42" <br />42" <br />Sump Depth: <br />75 %i" <br />75''/2" <br />75" <br />74" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />35" <br />32" <br />No Piping <br />Penetrations <br />19" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />43" <br />43" <br />44" <br />33" <br />Condition of sump prior to <br />testing: <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of Sump Tested <br />Water Line 44" <br />Water Line 45" <br />Water Line 45" <br />Water Line 40" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />water and starting test: <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />Test Start Time: <br />9:00 <br />9:05 <br />9:10 <br />9:50 <br />Initial Reading (R,): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test End Time: <br />9:30 <br />9:35 <br />9:40 <br />10:20 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF -R,): <br />0 <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />Pass <br />Pass <br />Pass <br />Pass <br />Is there a sensor in the sump? <br />Yes <br />Yes <br />Yes <br />Yes <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor removed for testing? <br />1`es <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced and <br />verified functional after testing? <br />}'es <br />Yes <br />Yes <br />Yes <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />