Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone. (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />Facility Address: <br />ate: <br />Tillanuary'11,2016 <br />COLLEGEVILLE MARKET & CAF; <br />13521 E MARIPOSA RD, STOCKTON <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />723 <br />CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping. <br />Corrosion protection for the buried piping was not addressed in the SPCC Plan. The existence of corrosion protection <br />could not be determined during the inspection. Buried piping that is installed or replaced after August 16, 2002, shall <br />be provided with a protective wrapping and coating and cathodically protected. Immediately provide all buried piping <br />installed on or after August 16, 2002, a protective wrapping and coating and cathodic protection. <br />This is a Class II violation. <br />726 <br />CFR 112.8(d)(4) Failed to regularly inspect aboveground valves, piping, and appurtenances. <br />No inspection records were available on site for piping, valves, and appurtenances. According to Mr. Mathews, the <br />inspections have not been conducted recently. All aboveground valves, piping, and appurtenances shall be regularly <br />inspected. Immediately inspect aboveground valves, piping, and appurtenances and ensure inspections are done <br />regularly, or provide equivalence as allowed by CFR 112.7(a). <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by February 10, 2016. <br />Please be aware as of January 1, 2013, all businesses are required to submit all new (or any changes to existing) <br />Aboveground Petroleum Storage Act (APSA) information online to the California Environmental Reporting System <br />(CERS) at http://cers.calepa.ca.gov in addition to any other relevant activities and required fields. No later than <br />January 1, 2014, all APSA data must be entered and or updated in CERS. <br />Documents reviewed: SPCC Plan, Vapor Recovery Inspection logs <br />Documents provided: Return to Compliance Certification form, Schedule of free CUPA classes <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br />FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received By <br />Received By (printed name and title): <br />Date: <br />0 <br />(signature): <br />Phillip Mathews, Partner <br />of <br />Inspector _ <br />Inspector (printed name and title): <br />Inspector Phone: <br />(signat -� ---�� <br />STACY RIVERA, Senior REHS <br />(209) 468-3440 <br />Page 7 of 7 <br />