1,C\TATC <br /> ASSOCIATES I N C . <br /> Groundwater Pumping Test Report <br /> ' Sunwest Liquors <br /> 2449 West Kettleman Lane <br /> ' Lodi, California <br /> ATC Project No. 54.25957.0001 <br /> 1 <br /> 1.0 INTRODUCTION <br /> ' ATC Associates Inc. has prepared this Groundwater Pumping test Report on behalf of Sunwest <br /> Liquors to summarize findings of the groundwater extraction pilot test at the above referenced <br /> ' site. The purpose of the pilot test was to evaluate if groundwater extraction is a viable remedial <br /> option for remediating petroleum impacted groundwater in the vicinity of the former <br /> ' underground storage tanks (USTs). This work was done at the request of San Joaquin County <br /> Environmental Health Department (SJCEHD). The findings of the pilot study are summarized in <br /> the following paragraphs. <br /> 1.11 Site Location <br /> The site is located on the northeast corner of the intersection of West Kettleman Lane and Lower <br /> Sacramento Road on the west side of the City of Lodi, California, as shown on Figure 1. The <br /> location is a commercial and residential area. The site is currently occupied by a-Starbuck's <br /> 1 Coffee. <br /> 1.2 Back round <br /> 1 On July 10, 1998, Thorpe Oil removed three gasoline USTs from the site. Soil samples taken <br /> from the excavation of the USTs and the related dispenser piping indicated that the soil was <br /> ' impacted with petroleum hydrocarbons. <br /> In August 1998, Geomatrix Consultants advanced four soil borings to determine the vertical and <br /> horizontal extent of the petroleum hydrocarbon plume. One of these soil borings, approximately <br /> 25 feet south of the UST excavation, was completed as groundwater monitoring well GMX-1. <br /> In June 1999, Foothill Engineering supervised the advancement of three-additional soil borings; <br /> which were completed as groundwater monitoring wells MW-2, MW-3, and MW-4. From July <br /> ' 1999 to the date of this report, quarterly monitoring was conducted under the supervision of <br /> Foothill Engineering. <br /> wi25957Veportslpumptest.doc I <br />