My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
574
>
2300 - Underground Storage Tank Program
>
PR0231405
>
BILLING PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/29/2024 1:16:56 PM
Creation date
10/26/2018 2:04:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231405
PE
2361
FACILITY_ID
FA0003164
FACILITY_NAME
NORTH POLE GAS & FOOD INC
STREET_NUMBER
574
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
574 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
173
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. ^lspvnt.'i C <br />STATE OF CALIFORNIA <br />STATE WATER RESOURCES CONTROL BOARD u n v <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br />COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br />B. MANUFACTURED BY: <br />t FI`1 <br />D. TANK CAPACITY IN GALLONS: fit' UIfIl'-" L" <br />A. TYPE OF <br />SYSTEM <br />❑ 2 SINGLE WALL <br />. I <br />MARK ONLY <br />���III 1 NEW PERMIT bl ❑ <br />3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION <br />❑ <br />7 PERMANENTLY CLOSED ONSITE <br />ONE ITEM <br />2 INTERIM PERMIT ❑ <br />4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE <br />❑ <br />8 TANK REMOVED <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED:j <br />r� c y/ <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />I TANK nFsrRIPTION COMPLETE ALL ITEMS - SPECIFY IF UNKNOWN <br />A. OWNER'S TANK I. D. # <br />B. MANUFACTURED BY: <br />C. DATE INSTALLED (MO/DAY/YEAR) 7 % � <br />D. TANK CAPACITY IN GALLONS: fit' UIfIl'-" L" <br />II TANK rnNTFNT9 IF A-1 IS MARKED COMPLETE ITEM C. <br />A. I MOTOR VEHICLE FUEL ❑ 4 OIL <br />a 2 PETROLEUM ❑ 80 EMPTY <br />❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN <br />B.C. <br />PRODUCT <br />x <br />❑ 2 WASTE <br />to REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br />❑ 1b PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br />❑ 1c MIDGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br />❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM 0. BELOW) <br />D. IF (A.1) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C. A. S. #: <br />111 TANK rnNSTRI IrTION MARK ON1F ITEM ONLY IN BOXES A. B. AND C. AND ALL THAT APPLIES IN BOX D AND E <br />Ill DIDIAIr: INPnAUATInN r,arl c A IF ARnVF nFInIIND OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. SYSTEM TYPE <br />p 1 DOUBLE WALL <br />❑ 3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br />A. TYPE OF <br />SYSTEM <br />❑ 2 SINGLE WALL <br />❑ 4 SINGLE WALL IN A VAULT <br />❑ 99 OTHER <br />A 4)2 DOUBLE WALL <br />❑ 1 BARE STEEL <br />❑ 2 STAINLESS STEEL <br />3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 7 ALUMINUM <br />8 100% METHANOL COMPATIBLE W/FRP <br />(Primary Tank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />PROTECTION <br />❑ I RUBBER LINED <br />O 2 ALKYD LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />LINING OR <br />kn 5 GLASS LINING <br />❑ 6 UNLINED❑ <br />5 UNKNOWN <br />❑ 99 OTHER <br />COATING <br />IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? <br />YES NO— <br />D. EXTERIOR <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑ 3 VINYL WRAP <br />4 FIBERGLASS REINFORCED PLASTIC <br />CORROSION <br />❑ 5 CATHODIC PROTECTION <br />❑ 91 NONE <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />PROTECTION <br />SPILL CONTAINMENT <br />INSTALLED (YEAR)[_[_ <br />OVERFILL PREVENTION EQUIPMENT INSTALLED (YEAR) <br />E. SPILL AND OVERFILL, @tC. DROP TUBE YES <br />NO STRIKER LATE YES NO <br />DISPENSER CONTAINMENT YES NO <br />Ill DIDIAIr: INPnAUATInN r,arl c A IF ARnVF nFInIIND OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. SYSTEM TYPE <br />A �7 SUCTION <br />A U 2 PRESSURE <br />A U <br />3 GRAVITY A U <br />4 FLEXIBLE PIPING A U 99 OTHER <br />B. CONSTRUCTION <br />A U 1 SINGLE WALL <br />A 4)2 DOUBLE WALL <br />A U <br />3 LINED TRENCH A U <br />95 UNKNOWN A U 99 OTHER <br />C. MATERIAL AND <br />A U 1 BARE STEEL <br />A U 2 STAINLESS STEEL <br />A U <br />3 POLYVINYL CHLORIDE (PVC)A04 FIBERGLASS PIPE <br />CORROSION <br />A U 5 ALUMINUM <br />A U 6 CONCRETE <br />A U <br />7 STEELW/COATING <br />A U 8 100% METHANOL COMPATIBLEW/FRP <br />PROTECTION <br />A 6)9 GALVANIZED STEEL <br />A U 10 CATHODIC PROTECTION <br />A U 95 UNKNOWN <br />A U 99 OTHER <br />D. LEAK DETECTION <br />1 MECHANICAL UNE LEAK 1:12 <br />DETECTOR <br />LINE TIGHTNESS ® 3 CONTINUOUS INTERSTITIAL ❑ 4 ELECTRONIC LINE ❑ <br />TESTING MONITORING LEAK DETECTOR <br />5 AUTOMATIC PUMP O 99 OTHER <br />SHUTDOWN <br />V. TANK LEAK DETECTION <br />F-1 1 VISUAL CHECK ID RECONCILIATION <br />RECONCILIATIONORY ❑ 3 MONIITORING VAOZE ❑ 4 AUTOMATGAUGING IC TANK ❑ 5 GROUND MON TORINGTER ❑ 6 TAENSTINGTANK <br />MANUAL 7 <br />CONTINUS MONITORU INTERSTITIAL ❑ 8 SIR ❑ 9 WENK LY MANUAL [:]10 MONTESTTHLY TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION (PERMANENT CLOSURE IN-PLACE) <br />1. ESTIMATED DATE LAST USED (MO/DAYNR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH YES ❑ NO ❑ <br />SUBSTANCE REMAINING GALLONS INERT MATERIAL 7 <br />TNI.s FnRM HA.S PFFN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, 1S TRUE AND CORRECT <br />TANK OWNER'S NAME � �- // DATE <br />(PRINITEDBSIGNATURE) �//�/r <br />nrA 1 ArrCnlrrV I ICD nKII V TUG QTAT>= I n NUMBER IS COMPOSFn OF THF FOUR NUMBERS BELOW <br />THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION . FORM A, UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. I ms runts <br />SHOULD BE ACCOMPANIED BY A PLOT PLAN. FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br />FORM 8 (6-95) <br />COUNTY # JURISDICTION # FACILITY # TANK # <br />STATE I.D.# <br />m <br />PERMIT NUMBER <br />PERMIT APPROVED BY/DATE <br />PERMIT EXPIRATION DATE <br />THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION . FORM A, UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. I ms runts <br />SHOULD BE ACCOMPANIED BY A PLOT PLAN. FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br />FORM 8 (6-95) <br />
The URL can be used to link to this page
Your browser does not support the video tag.