Laserfiche WebLink
•CGS <br />STATE OF CALIFORNIA 2 <br />STATE WATER RESOURCES CONTROL BOARD sy <br />UNDERGROUND STORAGE TANK PERMIT -APPLICATION - FORM B " <br />o <br />COMPLETE A SEPARATE FORM FOR CH TANK SYSTEM. <br />MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION❑ 7 P ANENTLY CLOSE _ ON SITE <br />ONE ITEM `❑ 2 INTERIM PERMIT ❑I a AMENDED PERMIT 6 TEMPORARY TANK CLOSURE 6 TANK REMOVED v / <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED:' <br />I. TANK DESCRIPTION COMPLETE ALL ITEMS - SPECIFY IF UNKNOWN <br />A OWNER'S TANK I. D. # <br />3 <br />B. MANUFACTURED BY: UNKNOWN <br />C. DATE INSTALLED (MO/DAYNEAR) <br />L�� PRODUCT <br />D. TANK CAPACITY IN GALLONS: r <br />II. TANK CONTENTS IF A-1 IS MARKED, COMPLETE ITEM C. <br />A n/ 1 MOTOR VEHICLE FUEL C❑ 4 OIL <br />B. <br />C ❑] REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br />Dl(` -_LTJ 2 PETROLEUM F7PREMIUM <br />BO EMPTY <br />L�� PRODUCT <br />.1 La <br />Ute' UNLEADED E:]4 GASAHOL ❑ 7 METHANOL <br />❑ is MIDGRADE UNLEADED ❑ 5 JET FUEL ❑ B M85 <br />❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOM <br />D. IF (A.1) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C. A. S. #: <br />III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A, B. AND C, AND ALL THAT APPLIES IN BOX D AND E <br />A. TYPE OF <br />❑ 1 DOUBLE WALL <br />❑ 3 SINGLE WALL WITH EXTERIOR UNER <br />❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br />SYSTEM <br />2 SINGLE WALL <br />F74 SINGLE WALL IN A VAULT <br />El 99 OTHER <br />B. TANK <br />/--'t 1 BARE STEEL <br />❑ 2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 7 ALUMINUM <br />❑ 8 100% METHANOL COMPATIBLE W/FRP <br />(Primary Tank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />C. INTERIOR <br />1 RUBBER LINED <br />F7❑ <br />2 ALKYD LINING <br />3 EPDXY UNING <br />4 PHENOLIC LINING <br />LINING OR <br />F75 GLASS LINING <br />❑ 6 UNUNED <br />❑ 95 UNKNOWN <br />oo !� <br />ER, 99 OTHER ��11-U��� <br />COATING <br />IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? <br />YES_ NO— <br />A U 99 OTHER <br />D. EXTERIOR <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑� 3 VINYL WRAP <br />❑ 4 FIBERGLASS REINFORCED PLASTIC <br />CORROSION <br />❑ 5 CATHODIC PROTECTION <br />❑ 91 NONE <br />�TII��yy <br />�95 UNKNOWN <br />❑ 99 OTHER <br />PROTECTION <br />LEAK DETECTOR <br />TD <br />SHUTDOWN <br />E. SPILL AND OVERFILL, BIC. SPILL CONTAINMENT INSTALLED (YEAR) <br />OVERFILL PREVENTION EQUIPMENT INSTALLED (YEAR) <br />DROP TUBE YES <br />NO STRIKER PLATE <br />YES NO <br />DISPENSER CONTAINMENT YES NO <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND, BOTH IF APPLICABLE <br />A. SYSTEM TYPE <br />A U <br />1 SUCTION <br />A(gt PRESSURE <br />A U <br />3 GRAVITY <br />A U <br />A FLEXIBLE PIPING A U 99 OTHER <br />B. CONSTRUCTION <br />A U <br />1 SINGLE WALL <br />A U 2 DOUBLE WALL <br />A U <br />3 LINED TRENCH <br />A U <br />5 UNKNOWN A U 99 OTHER <br />C. MATERIAL AND <br />A U <br />1 BARE STEEL <br />A U 2 STAINLESS STEEL <br />A U <br />3 POLYVINYL CHLORIDE (PVC) A U 4 FIBERGLASS PIPE <br />CORROSION <br />A U <br />5 ALUMINUM <br />A U 6 CONCRETE <br />A U <br />7 STEEL W/COATING <br />A U 8 100% METHANOL COMPATIBLE W/FRP <br />PROTECTION <br />A U <br />9 GALVANIZED STEEL <br />A U 10 CATHODIC PROTECTION <br />A U 5 UNKNOWN <br />A U 99 OTHER <br />D. LEAK DETECTION <br />1 MECHANICAL LINE LEAK [g <br />2 UNE TIGHTNESS ❑ 3 CONTINUOUS INTERST LkL [:]4 ELECTRONIC LINE <br />7]5 <br />AUTOMATIC PUMP ❑ 99 OTHER <br />CTOR <br />TESTING MONITORING <br />LEAK DETECTOR <br />TD <br />SHUTDOWN <br />V. TANK LEAK DETECTION <br />❑NUAL <br />1 VISUAL CHECK ❑ 2 RECO CILIATIONMANUAL INVENTORY ❑ 3 MONITORING � VADOZE4 GAUGING AUTOMATIC TANK L75 MONITORING GROUND WATER ❑ 6 TEESTINGTANK <br />❑ 7 MON TORIOU INTERSTITIAL ❑ 6 SIR ❑ 9 WEEK LY MANUAL ❑ 10 MONTHLY TANK ❑ 95 UNKNOWN El 99 OTHER <br />VI. TANK CLOSURE INFORMATION (PERMANENT CLOSURE IN-PLACE) <br />1. ESTIMATED DATE LAST USED (MO/DAY/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH YES ❑ NO ❑ <br />SUBSTANCE REMAINING GALLONS INERT MATERIAL ? <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br />(PRINTED DATE <br />TANK OWNER'S A SIGNATURE) E SA NAM SAN C'/ . Da�+f 7 -OOP, <br />LOCAL AGENCY USE ONLY THE STATE I.D. NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />COUNTY # JURISDICTION # FACILITY # L+ TANK # <br />STATE I. D.# ❑ i D �� ^, <br />PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE �j _ /A <br />THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPI )N - FORM A, UNLESS A CURRENT FORM A HAS BEEN FILED. C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br />SHOULD BE ACCOMPANIED BY A PLOT 1 -ILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING TH 9GROUND STORAGE TANK REGULATIONS q,0 1 <br />FORMS (6-95) �IO 111191// ��(P11 <br />