My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1999 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
574
>
2300 - Underground Storage Tank Program
>
PR0231405
>
COMPLIANCE INFO 1999 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 4:42:14 PM
Creation date
10/26/2018 3:21:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 1999 - 2007
FileName_PostFix
1999 - 2007
RECORD_ID
PR0231405
PE
2361
FACILITY_ID
FA0003164
FACILITY_NAME
A ONE GAS & FOOD
STREET_NUMBER
574
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
574 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> hNVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street,Stockton,California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:v✓ww.s* o_v_.org_/ehd <br /> UNDERGROUND STORAGE TANK UST PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date: <br /> A- 1 006 t Wd jj�,,4 �7 <br /> Facility address: �kA <br /> UST# <br /> I , <br /> 1✓tn r� ► +i Product <br /> flit Contact: � Tltle: Phone: <br /> l/" p�{lul/�hf�n��l( <br /> icor' P el: IN Pi ing system: Ov mill prevention: <br /> Pressurized ❑Suction ❑GravitMechanical ❑Audible/visual <br /> pection type: Violations: <br /> Routine Monitoring Certification ❑Installation ❑Other: ❑MI-RDetect ❑M2-RPrev I I M-3 Both <br /> VIOLATION(S) HSC=California Health&Safety Code;CCR=California Code of Regulations V R <br /> # Code Section V <br /> V=Violation;RV=R eat Violation <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 b & c Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 b Monitoring Program(Monitoring&Response Plan is current and approved by the local agency. <br /> 6 CCR 2712 i) Monitoring plan is onsite. <br /> 7 CCR 2712 b Maintenance&monitoring records M 1 <br /> 8 CCR 2643 d) Daily monitoring of suction i in (pre-January, 1, 1984) <br /> 9 HSC 25292.1 UST system is operated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present (M1) <br /> 11 CCR 2630 d UST system monitoring equipment is properly located to detect a leak M1 <br /> 12 HSC 25291 UST system monitoring equipment isoperational (M2) <br /> 13 CCR 2636 1 Continuous monitoring system for underground piping&UDC is present M1) <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 Line leak detector(s) are installed M1) <br /> 18 CCR 2635(b)(1) Spill container (M2) <br /> 19 CCR 2635(b)(2) Overfill prevention system (M2) <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&2°containment <br /> 21 HSC 25291 (e) Water in 2°containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases M1) <br /> 23 CCR 2715 DesignatedOperator:(a)Statement from UST owner; (c-e)Monthly inspection; f)Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 1 CCR 2638 a) Annual line leak detector test (M1) <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636 4 Annual line tightness test M1) <br /> 28 CCR 2661 f) Repair for tank/piping has had tightness test (M2) <br /> 29 CCR 2643 e) Biennial tightness test of gravity piping(pre-January 1, 1984 <br /> 30 CCR 2643 d) Triennial line test for conventional suction piping(pre-January1, 1984) (M1) <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> 34 HSC 25298 b) Permit to tem raril dose UST system <br /> 35 1 HSC 25298 c Permit to close UST system <br /> 36 HSC 25299(a)(9) I Disabling leak detection devices <br /> 37 HSC 25298 a) IIlegal abandonment of UST system <br /> 38 Other: _ <br /> D 1 'P MT <br /> PHONE- UIC <br /> Septic system: <br /> RAI' vill 3/ 7 Serves 2:20 people/day <br /> ECEIVED BY: 'TIT LE: -Receives other than sanitary waste <br /> Other disposal methods: <br /> Dry wells/French Drains <br /> EHD 23-02-002 REV 05/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.