INSTALL 1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
574
>
2300 - Underground Storage Tank Program
>
PR0231405
>
INSTALL 1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2019 2:06:00 PM
Creation date
10/26/2018 3:48:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL 1999
FileName_PostFix
1999
RECORD_ID
PR0231405
PE
2361
FACILITY_ID
FA0003164
FACILITY_NAME
A ONE GAS & FOOD
STREET_NUMBER
574
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
574 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br />a <br />Aw <br />Figure A: Troublesh ooting GuideFor <br />t Control <br />ftis <br />Model SBOO11C - Single Circuit Control Panel <br />Test <br />Test Results <br />Conclusion <br />Alarm <br />Alarm <br />Normal <br />Bell <br />Light <br />Light <br />1.0 Symptom: Reservoir Full. <br />ON <br />ON <br />OFF <br />I.1 Check Liquid Media. <br />Remove sensor from reservoir. <br />OFF <br />OFF <br />ON <br />Replace Fluid <br />Insert sensor in container fresh water. <br />ON <br />ON <br />OFF <br />Proceed to Test 1.2 <br />1.2 Check Relay [SRI. <br />ON <br />ON <br />OFF <br />Replace Relay [SRI <br />Jumper terminals G & L on relay ISR 1. <br />OFF <br />OFF <br />ON <br />Proceed to Test 1.3 <br />1.3 Check Pushbutton or Sensor. <br />ON <br />ON <br />OFF <br />Replace pushbutton switch <br />Jumper terminals S 1-G 1 on terminal strap. <br />OFF <br />OFF <br />ON <br />Inspect sensor and wiring <br />for defects <br />2.0 Symptom: Alarm Bell Will Not Silence <br />N/A <br />N/A <br />N/A <br />2.1 Check Silencer Button. <br />N/A <br />N/A <br />N/A <br />Replace pushbutton <br />2.2 Check Relay R2. <br />N/A <br />N/A <br />N/A <br />Replace relay R2 <br />3.0 Symptom: Panel Normal - Pump Cutoff, <br />OFF <br />OFF <br />ON <br />Contacts Open <br />3.1 Check Relay R1. <br />N/A <br />N/A <br />N/A <br />Replace relay R1 <br />Model SB0014C-Four Circuit Control Panel <br />Note: The Normal Light Will Be On Only When All Channels <br />Are Normal <br />Test <br />Test Results <br />Conclusion <br />Alarm <br />Alarm <br />Normal <br />Bell <br />Light <br />Light <br />1.0 Symptom: Reservoir Full <br />ON <br />ON <br />OFF <br />1.1 Check Liquid Media. Remove Sensor from <br />reservoir. Insert sensor in container of fresh <br />OFF <br />OFF <br />ON <br />Replace fluid <br />water. <br />ON <br />ON <br />OFF <br />Proceed to Test 1.2 <br />1.2 Check ISR I Relay. Jumper sensor terminals <br />corresponding to channel alarming (i.e. <br />OFF <br />OFF <br />ON <br />Check field wiring <br />channel 1 terminal pairs S 1 and G 1). <br />ON <br />ON <br />OFF <br />Proceed to Test 1.3 <br />1.3 Verify Switches and Pots Are Set <br />Correctly -Consult factory before <br />Switches and pots set correctly <br />and <br />Replace ISR I relay <br />changing settings <br />system alarming. <br />2.0 Symptom: Reservoir Full <br />ON <br />OFF <br />ON <br />2.1 Check ISR 1 Relay <br />N/A <br />N/A <br />N/A <br />Replace [SRI relay <br />3.0 Symptom: Reservoir Full <br />ON <br />OFF <br />OFF <br />3.1 Check Warning Light Bulb <br />N/A <br />N/A <br />N/A <br />Replace burned out bulb <br />4.0 Symptom: Reservoir Full <br />OFF <br />ON <br />OFF <br />4.1 Check ISR 1 Relay <br />N/A <br />N/A <br />N/A <br />Replace ISR I relay <br />5.0 Symptom: Reservoir Overfilled or Empty <br />OFF <br />OFF <br />ON <br />5.1 Push Test Button on Control Panel. <br />ON <br />ON <br />OFF <br />Proceed to Test 5.2 <br />OFF <br />OFF <br />ON <br />Replace [SRI relay <br />5.2 Check Field Wiring. Remove sensor <br />ON <br />ON <br />OFF <br />Replace sensor.* <br />from reservoir and disconnect sensor wiring <br />OFF <br />OFF <br />ON <br />Field wiring shorted.* <br />at junction box. <br />*Note: The monitoring circuit can appear normal if water is present in the junction box or conduit. <br />Water can saturate <br />the splice connections and mask an <br />alarm signal. BE SURE ALL WIRING AND TERMINATIONS ARE PROTECTED FROM MOISTURE. <br />29 <br />
The URL can be used to link to this page
Your browser does not support the video tag.