INSTALL 1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
574
>
2300 - Underground Storage Tank Program
>
PR0231405
>
INSTALL 1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2019 2:06:00 PM
Creation date
10/26/2018 3:48:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL 1999
FileName_PostFix
1999
RECORD_ID
PR0231405
PE
2361
FACILITY_ID
FA0003164
FACILITY_NAME
A ONE GAS & FOOD
STREET_NUMBER
574
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
574 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. Tank Inspection Procedures <br />a. Underwriter Laboratories label number (to correspond with invoices <br />and UL label on tank.) <br />b. Tank nominal capacity (gallons) <br />c. Tank Measurements in inches (see instructions below) to confirm that <br />tank has proper support. <br />1 .After pressure test, measure tank internal diameter prior to backfilling <br />2.After backfill is at subgrade, measure from tank bottom to top of fill <br />tube prior to insertion of drop tube. <br />3.After backfill is at subgrade prior to insertion of drop tube, measure <br />from bottom of the fitting to the top of the fill tube. <br />4.Calculated tank internal diameter with backfill at subgrade <br />(subtract measurement #3 from measurement #2). <br />5.Calculated tank deflection (subtract measurement #4 from <br />measurement #1). <br />Tai... Number <br />2 3 4 5 <br />Measurement Instructions <br />All measurements for vertical deflection are made from the bottom of the tank to the bottom of the fitting. <br />All measurements should be made in inches using a standard nonmetallic gauge stick. <br />All measurements should be made through the fill tube fitting. <br />Measurement 1 may be made above ground or in hole prior to backfilling. <br />Measurement 2 must be made prior to insertion of drop tube, but after fill pipe has been installed. <br />Measurement 1 is the inside diameter <br />read intoes of the tank at the gauge opening. <br />Measure from the bottom of the tank <br />to the bottom of the fitting. This <br />measurement should be taken prior to <br />meas ,emem placing any backfill. Record measure- <br />ment 1. <br />Measurement 2 is the distance from <br />a mcnes the bottom of the tank to the top of <br />the fill tube. This measurement should <br />be taken prior to insertion of the drop <br />tube. Backfill should be to subgrade at <br />---1 2 this time. Record measurement 2. <br />Measurement 3 is the distance from <br />the bottom of the fitting to the top of <br />the fill tube. This measurement is <br />nad taken by driving a nail into the 1" point <br />at a right angle to the gauge stick. <br />measurement 3 <br />Lower the gauge stick down the fill <br />tube far enough to extend below the <br />bottom of the fitting. Lift the gauge <br />stick until the nail catches on the <br />lip of the fitting. Read measurement at <br />the top of the fill pipe. Subtract 1" to <br />allow for the point where the nail is in <br />the gauge stick. <br />on* <br />1@)� <br />FLUID <br />CONTAINMENT <br />Pub. No. 16756-B Litho U.S.A. March, 1995 Copyright ©1995 Fluid Containment Inc. <br />Measurement 4 is the calculated tank internal diameter (subtract <br />measurement 3 from measurement 2). <br />Measurement 5 is the calculated tank internal deflection <br />(subtract measurement 4 from measurement 1). <br />WARNING: If the answer in measurement #5 is in excess of the <br />appropriate value shown in Table A, immediately contact the <br />manufacturer's installation manager prior to proceeding with the <br />installation. <br />Table A <br />Tank <br />Diameter <br />Maximum <br />Deflection <br />4' <br />1/2" <br />6' <br />3/4" <br />8' <br />1-1/4" <br />10' <br />1-1/2" <br />12' <br />1-1/2" <br />'For warranty details, see Publications on <br />Single -Wall Fiberglass Tanks for Underground <br />Petroleum Storage, Pub. No. 6312 and Double - <br />Wall Fiberglass Tanks for Underground <br />Petroleum Storage, Pub. No. 16207. <br />Installation was in accordance with Fluid Containment Pub. No. <br />6304. <br />Owner's Representative Title <br />Contractor's Representative <br />Notary Public <br />Date <br />NOTE: Owner must retain this document to substantiate any <br />future structural warranty claim. <br />Tait Technical Support (409) 756-7732 <br />